Transcatheter valve-in-valve implantation for failed bioprosthetic heart valves.

Webb John G, Wood David A, Ye Jian, Gurvitch Ronen, Masson Jean-Bernard, Rodés-Cabau Josep, Osten Mark, Horlick Eric, Wendler O, Dumont Eric, Carere Ronald G, Wijesinghe Namal, Nietlispach Fabian, Johnson Mark, Thompson Chrisopher R, Moss Robert, Leipsic Jonathon, Munt Brad, Lichtenstein Samuel V, Cheung Anson

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The majority of prosthetic heart valves currently implanted are tissue valves that can be expected to degenerate with time and eventually fail. Repeat cardiac surgery to replace these valves is associated with significant morbidity and mortality. Transcatheter heart valve implantation within a failed bioprosthesis, a "valve-in-valve" procedure, may offer a less invasive alternative.

METHODS AND

RESULTS

Valve-in-valve implantations were performed in 24 high-risk patients. Failed valves were aortic (n=10), mitral (n=7), pulmonary (n=6), or tricuspid (n=1) bioprostheses. Implantation was successful with immediate restoration of satisfactory valve function in all but 1 patient. No patient had more than mild regurgitation after implantation. No patients died during the procedure. Thirty-day mortality was 4.2%. Mortality was related primarily to learning-curve issues early in this high-risk experience. At baseline, 88% of patients were in New York Heart Association functional class III or IV; at the last follow-up, 88% of patients were in class I or II. At a median follow-up of 135 days (interquartile range, 46 to 254 days) and a maximum follow-up of 1045 days, 91.7% of patients remained alive with satisfactory valve function.

CONCLUSIONS

Transcatheter valve-in-valve implantation is a reproducible option for the management of bioprosthetic valve failure. Aortic, pulmonary, mitral, and tricuspid tissue valves were amenable to this approach. This finding may have important implications with regard to valve replacement in high-risk patients.

Для цитирования: Webb John G, Wood David A, Ye Jian, Gurvitch Ronen, Masson Jean-Bernard, Rodés-Cabau Josep, Osten Mark, Horlick Eric, Wendler O, Dumont Eric, Carere Ronald G, Wijesinghe Namal, Nietlispach Fabian, Johnson Mark, Thompson Chrisopher R, Moss Robert, Leipsic Jonathon, Munt Brad, Lichtenstein Samuel V, Cheung Anson. Transcatheter valve-in-valve implantation for failed bioprosthetic heart valves.. Circulation. 2010. DOI: 10.1161/circulationaha.109.924613.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.