MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/2331216515616942

Медицинская библиотека · Trends in hearing · 2015

Direct Intracochlear Acoustic Stimulation Using a PZT Microactuator.

Luo Chuan, Omelchenko Irina, Manson Robert, Robbins Carol, Oesterle Elizabeth C, Cao Guo Zhong, Shen I Y, Hume Clifford R

СтатьяПоддержка NIH: внешняя программаПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

Combined electric and acoustic stimulation has proven to be an effective strategy to improve hearing in some cochlear implant users. We describe an acoustic microactuator to directly deliver stimuli to the perilymph in the scala tympani. The 800 µm by 800 µm actuator has a silicon diaphragm driven by a piezoelectric thin film (e.g., lead-zirconium-titanium oxide or PZT). This device could also be used as a component of a bimodal acoustic-electric electrode array. In the current study, we established a guinea pig model to test the actuator for its ability to deliver auditory signals to the cochlea in vivo. The actuator was placed through the round window of the cochlea. Auditory brainstem response (ABR) thresholds, peak latencies, and amplitude growth were calculated for an ear canal speaker versus the intracochlear actuator for tone burst stimuli at 4, 8, 16, and 24 kHz. An ABR was obtained after removal of the probe to assess loss of hearing related to the procedure. In some animals, the temporal bone was harvested for histologic analysis of cochlear damage. We show that the device is capable of stimulating ABRs in vivo with latencies and growth functions comparable to stimulation in the ear canal. Further experiments will be necessary to evaluate the efficiency and safety of this modality in long-term auditory stimulation and its ability to be integrated with conventional cochlear implant arrays.

Для цитирования: Luo Chuan, Omelchenko Irina, Manson Robert, Robbins Carol, Oesterle Elizabeth C, Cao Guo Zhong, Shen I Y, Hume Clifford R. Direct Intracochlear Acoustic Stimulation Using a PZT Microactuator.. Trends in hearing. 2015. DOI: 10.1177/2331216515616942.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.