MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-022-08743-1

Медицинская библиотека · European radiology · 2022

Superiority of [68Ga]Ga-FAPI-04/[18F]FAPI-42 PET/CT to [18F]FDG PET/CT in delineating the primary tumor and peritoneal metastasis in initial gastric cancer.

Fu Lilan, Huang Shun, Wu Hubing, Dong Ye, Xie Fei, Wu Ruihe, Zhou Kemin, Tang Ganghua, Zhou Wenlan

СтатьяОтозванная публикацияПеревод пока не подготовлен
Источник пометил публикацию как отозванную.

Аннотация

OBJECTIVE

This study aimed to compare [68Ga]Ga-FAPI-04/[18F]FAPI-42 PET/CT with [18F]FDG PET/CT in the evaluation of initial gastric cancer.

METHODS

We retrospectively compared [68Ga]Ga-FAPI-04/[18F]FAPI-42 PET/CT with [18F]FDG PET/CT in patients with initial gastric cancer from September 2020 to March 2021. Lesion detectability and the uptake of lesions quantified by the maximum standardized uptake value (SUVmax) and target-to-background ratio (TBR) were compared between the two modalities using the Wilcoxon signed-rank test, Mann-Whitney U test, and McNemar's chi-square test.

RESULTS

A total of 61 patients (37 males, aged 23-81 years) were included, of which 22 underwent radical gastrectomy. For primary lesions, higher uptake of [68Ga]Ga-FAPI-04/[18F]FAPI-42 was observed compared to [18F]FDG (median SUVmax, 14.60 vs 4.35, p < 0.001), resulting in higher positive detection using [68Ga]Ga-FAPI-04/[18F]FAPI-42 PET/CT than [18F]FDG PET/CT (95.1% vs 73.8%, p < 0.001), particularly for tumors with signet-ring cell carcinoma (SRCC) (96.4% vs 57.1%, p < 0.001). [68Ga]Ga-FAPI-04/[18F]FAPI-42 PET/CT detected more positive lymph nodes than [18F]FDG PET/CT (637 vs 407). However, both modalities underestimated N staging compared to pathological N staging. [68Ga]Ga-FAPI-04/[18F]FAPI-42 PET/CT showed a higher sensitivity (92.3% vs 53.8%, p = 0.002) and peritoneal cancer index score (18 vs 3, p < 0.001) in peritoneum metastasis and other suspect metastases compared to [18F]FDG PET/CT.

CONCLUSION

Our findings indicate that [68Ga]Ga-FAPI-04/[18F]FAPI-42 PET/CT outperformed [18F]FDG PET/CT in the evaluation of primary tumors with SRCC and peritoneum metastasis in initial gastric cancer. However, no clinically useful improvement was seen in N staging.

KEY POINTS: • The uptake of [68Ga]Ga-FAPI-04/[18F]FAPI-42 in primary tumor and metastasis was intensely higher than that of [18F]FDG (p < 0.001) in 61 patients with initial gastric cancer. • [68Ga]Ga-FAPI-04/[18F]FAPI-42 PET/CT had a higher sensitivity detection in primary tumors (95.1% vs 73.8%, p < 0.001) and peritoneal metastases (92.3% vs 53.8%, p = 0.002) than [18F]FDG PET/CT. • [68Ga]Ga-FAPI-04/[18F]FAPI-42 PET/CT depicted more positive lymph nodes than [18F]FDG PET/CT (637 vs 407); however, both underestimated N staging compared to pathological N staging.

Для цитирования: Fu Lilan, Huang Shun, Wu Hubing, Dong Ye, Xie Fei, Wu Ruihe, Zhou Kemin, Tang Ganghua, Zhou Wenlan. Superiority of [68Ga]Ga-FAPI-04/[18F]FAPI-42 PET/CT to [18F]FDG PET/CT in delineating the primary tumor and peritoneal metastasis in initial gastric cancer.. European radiology. 2022. DOI: 10.1007/s00330-022-08743-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.