Leung Thomas W, Yu Simon C H, Lam Wynnie W M, Chan Anne Y Y, Lau Alexander Y L, Wong Lawrence K S
Аннотация
BACKGROUND AND PURPOSE: A major concern of intracranial stenting is perforator infarction. It is unclear whether the sustained radial force of a self-expanding stent or subsequent stent restenosis would cause late occlusion of perforators.
METHODS: We compared the baseline and poststent (>or=4 months) MRI scans of patients who underwent self-expanding stenting for recurrent ischemic symptoms attributed to a MCA stenosis >or=60%. New infarcts in the ipsilateral striatocapsular region were recorded.
RESULTS: MCA stenting was technically successful in 23 of 24 recruited patients. No new perforator territory infarct was found in follow-up MRI scans of all recruited patients. Postoperatively, all patients reported no further TIA or stroke over a median follow-up of 15 months.
CONCLUSIONS: The use of a self-expanding stent in patients with high-grade MCA stenosis may not pose a major risk to the perforators.
METHODS: We compared the baseline and poststent (>or=4 months) MRI scans of patients who underwent self-expanding stenting for recurrent ischemic symptoms attributed to a MCA stenosis >or=60%. New infarcts in the ipsilateral striatocapsular region were recorded.
RESULTS: MCA stenting was technically successful in 23 of 24 recruited patients. No new perforator territory infarct was found in follow-up MRI scans of all recruited patients. Postoperatively, all patients reported no further TIA or stroke over a median follow-up of 15 months.
CONCLUSIONS: The use of a self-expanding stent in patients with high-grade MCA stenosis may not pose a major risk to the perforators.