m+Medelevator.RU
← Поиск публикаций
Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2018

Is an Intravenous Injection of Gadolinium Really Necessary for Intralabyrinthine Schwannomas MR Examination?

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Karol Anne, Veillon Francis, Huynh Thaï, Severac François, Charpiot Anne, Venkatasamy Aïna

Аннотация

OBJECTIVES: Our aim was to confirm the usefulness of T2-weighted (T2W) gradient-echo sequence for detection and topographic diagnosis of intralabyrinthine schwannomas (ILS) compared with T1W contrast-enhanced sequence as gold standard, to evaluate the necessity of intravenous gadolinium injection for ILS follow-up imaging.

METHODS: Thirty patients with ILS were retrospectively enrolled and compared to a control group of 30 patients with no inner ear pathology. All patients underwent a T2W gradient-echo steady-state free precession (SSFP) acquisition at 3T, which was visually analyzed by two radiologists and compared to contrast-enhanced T1W sequence. A quantitative analysis was also performed, with the measurement of the tumor and inner ear signal on T2W images and the measurement of the tumor length in cochlear schwannomas.

RESULTS: T2W FIESTA-C sequence correctly diagnosed ILS with a sensitivity (Se) of 95% and a specificity (Sp) of 100%, with matching results for their topographic evaluation (Se 92%, Sp 98%) compared with the gold-standard. The difference between the two sequences was only 2.5%, with excellent interobserver agreement. The tumor signal on T2W images was significantly lower than the normal bright signal of the normal inner ear fluids (mean signal ratio = 0.42 vs 0.98).

CONCLUSION: The positive and topographic diagnostic accuracy of T2W FIESTA-C sequence was excellent compared with the T1W contrast-enhanced sequence, even though the latter remains easier and faster to analyze for an untrained radiologist. The performances of T2W gradient-echo sequence at 3T make it a reasonable alternative strategy for following ILS after they are diagnosed.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты