MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mao.0000000000001881

Медицинская библиотека · Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2018

Is an Intravenous Injection of Gadolinium Really Necessary for Intralabyrinthine Schwannomas MR Examination?

Karol Anne, Veillon Francis, Huynh Thaï, Severac François, Charpiot Anne, Venkatasamy Aïna

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Our aim was to confirm the usefulness of T2-weighted (T2W) gradient-echo sequence for detection and topographic diagnosis of intralabyrinthine schwannomas (ILS) compared with T1W contrast-enhanced sequence as gold standard, to evaluate the necessity of intravenous gadolinium injection for ILS follow-up imaging.

METHODS

Thirty patients with ILS were retrospectively enrolled and compared to a control group of 30 patients with no inner ear pathology. All patients underwent a T2W gradient-echo steady-state free precession (SSFP) acquisition at 3T, which was visually analyzed by two radiologists and compared to contrast-enhanced T1W sequence. A quantitative analysis was also performed, with the measurement of the tumor and inner ear signal on T2W images and the measurement of the tumor length in cochlear schwannomas.

RESULTS

T2W FIESTA-C sequence correctly diagnosed ILS with a sensitivity (Se) of 95% and a specificity (Sp) of 100%, with matching results for their topographic evaluation (Se 92%, Sp 98%) compared with the gold-standard. The difference between the two sequences was only 2.5%, with excellent interobserver agreement. The tumor signal on T2W images was significantly lower than the normal bright signal of the normal inner ear fluids (mean signal ratio = 0.42 vs 0.98).

CONCLUSION

The positive and topographic diagnostic accuracy of T2W FIESTA-C sequence was excellent compared with the T1W contrast-enhanced sequence, even though the latter remains easier and faster to analyze for an untrained radiologist. The performances of T2W gradient-echo sequence at 3T make it a reasonable alternative strategy for following ILS after they are diagnosed.

Для цитирования: Karol Anne, Veillon Francis, Huynh Thaï, Severac François, Charpiot Anne, Venkatasamy Aïna. Is an Intravenous Injection of Gadolinium Really Necessary for Intralabyrinthine Schwannomas MR Examination?. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2018. DOI: 10.1097/mao.0000000000001881.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.