MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circimaging.113.001156

Медицинская библиотека · Circulation. Cardiovascular imaging · 2014

Real-time magnetic resonance assessment of septal curvature accurately tracks acute hemodynamic changes in pediatric pulmonary hypertension.

Pandya Bejal, Quail Michael A, Steeden Jennifer A, McKee Andrea, Odille Freddy, Taylor Andrew M, Schulze-Neick Ingram, Derrick Graham, Moledina Shahin, Muthurangu Vivek

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

This study assesses the relationship between septal curvature and mean pulmonary artery pressure and indexed pulmonary vascular resistance in children with pulmonary hypertension. We hypothesized that septal curvature could be used to estimate right ventricular afterload and track acute changes in pulmonary hemodynamics.

METHODS AND

RESULTS

Fifty patients with a median age of 6.7 years (range, 0.45-16.5 years) underwent combined cardiac catheterization and cardiovascular magnetic resonance. The majority had idiopathic pulmonary arterial hypertension (n=30); the remaining patients had pulmonary hypertension associated with repaired congenital heart disease (n=17) or lung disease (n=3). Mean pulmonary artery pressure and pulmonary vascular resistance were acquired at baseline and during vasodilation. Septal curvature was measured using real-time cardiovascular magnetic resonance. There was a strong correlation between mean pulmonary artery pressure and SCmin at baseline and during vasodilator testing (r=-0.81 and -0.85, respectively; P<0.01). A strong linear relationship also existed between pulmonary vascular resistance and minimum septal curvature indexed to cardiac output both at baseline and during vasodilator testing (r=-0.88 and -0.87, respectively; P<0.01). Change in septal curvature metrics moderately correlated with absolute change in mean pulmonary artery pressure and pulmonary vascular resistance, respectively (r=0.58 and -0.74; P<0.01). Septal curvature metrics were able to identify vasoresponders with a sensitivity of 83% (95% confidence interval, 0.36-0.99) and a specificity of 91% (95% confidence interval, 0.77-0.97), using the Sitbon criteria. Idiopathic pulmonary arterial hypertension subgroup analysis revealed 3 responders with ΔSCmin values of 0.523, 0.551, and 0.568. If the middle value of 0.551 is taken as a cutoff, the approximate sensitivity would be 67% and the specificity would be 93%.

CONCLUSIONS

Septal curvature metrics are able to estimate right ventricular afterload and track acute changes in pulmonary hemodynamics during vasodilator testing. This suggests that septal curvature could be used for continuing assessment of load in pulmonary hypertension.

Для цитирования: Pandya Bejal, Quail Michael A, Steeden Jennifer A, McKee Andrea, Odille Freddy, Taylor Andrew M, Schulze-Neick Ingram, Derrick Graham, Moledina Shahin, Muthurangu Vivek. Real-time magnetic resonance assessment of septal curvature accurately tracks acute hemodynamic changes in pediatric pulmonary hypertension.. Circulation. Cardiovascular imaging. 2014. DOI: 10.1161/circimaging.113.001156.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.