MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.12286

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2013

Low mortality and low rate of perceived and documented arrhythmias after Cox maze III surgery for atrial fibrillation.

Johansson Birgitta I, Väärt Oskar, Edvardsson Nils, Nyström Britta, Scherstén Henrik, Karlsson Thomas, Berglin Eva

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

To report a long-term single-site experience of the cut-and-sew Cox maze III procedure for atrial fibrillation (AF).

METHODS

A total of 232 consecutive patients underwent the Cox maze III procedure for symptomatic therapy-refractory AF, with concomitant surgery in 34 patients. Follow-up data were obtained from electrocardiograms, patient visits, questionnaires, and medical files.

RESULTS

There were 103 patients (44%) with paroxysmal AF during 8.8 ± 6.5 years and 129 patients (56%) with nonparoxysmal AF for 7.3 ± 6.7 years. The preoperative New York Heart Association class was better in patients with paroxysmal AF (P < 0.0001); the left ventricular ejection fraction was 59 ± 7% versus 56 ± 8%, P = 0.003, and the left atrial area 24 ± 6 versus 27 ± 6 cm(2) , P = 0.01. Early and late postoperative adverse events occurred at similar rates. Four patients from each group died of reasons unrelated to surgery. The mean follow-up was 66 ± 42 (5-155) months. In total, 184/229 (80%) patients were free of documented AF/atrial flutter/atrial tachycardia (AF/AFl/AT) off antiarrhythmic drugs (AA) and 189/229 (83%) on or off AA. The hazard ratio (HR) for paroxysmal versus nonparoxysmal AF patients regarding documented AF/AFl/AT was 0.8 (95% confidence interval [CI] 0.4-1.4; P = 0.40). For patients without versus with concomitant surgery, the corresponding HR was 0.4 (95% CI 0.2-0.8; P = 0.008). Of 197 patients (89%) responding to the questionnaire, 41 had sought care for symptoms of arrhythmia, 29 of whom had documented AF/AFl/AT, whereas another six had other arrhythmias.

CONCLUSION

Cut-and-sew Cox maze III surgery provided long-lasting high efficacy, also in patients with nonparoxysmal AF of long duration and/or concomitant surgery, and was associated with low rates of subsequent adverse events.

Для цитирования: Johansson Birgitta I, Väärt Oskar, Edvardsson Nils, Nyström Britta, Scherstén Henrik, Karlsson Thomas, Berglin Eva. Low mortality and low rate of perceived and documented arrhythmias after Cox maze III surgery for atrial fibrillation.. Pacing and clinical electrophysiology : PACE. 2013. DOI: 10.1111/pace.12286.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.