DOI 10.1093/europace/eut021

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2013

Cryoballoon ablation of paroxysmal atrial fibrillation: 5-year outcome after single procedure and predictors of success.

Neumann Thomas, Wójcik Maciej, Berkowitsch Alexander, Erkapic Damir, Zaltsberg Sergey, Greiss Harald, Pajitnev Dimitri, Lehinant Stefan, Schmitt Jörn, Hamm Christian W, Pitschner Heinz F, Kuniss Malte

СтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIMS: Long-term efficacy following cryoballoon (CB) ablation of atrial fibrillation (AF) remains unknown. This study describes 5 years follow-up results and predictors of success of CB ablation in patients with paroxysmal atrial fibrillation (PAF).

METHODS AND

RESULTS

In total, 163 patients were enrolled with symptomatic, drug refractory PAF. Pulmonary vein isolation (PVI) with CB technique was performed. Primary endpoint of this consecutive single-centre study was first electrocardiogram-documented recurrence of AF, atrial tachycardia or atrial flutter (AFLAT). Five years success rate after single CB ablation was 53%. In 70% of the patients acute complete PVI was achieved with a single 28 mm balloon. The univariate predictors of AFLAT recurrence were (1) size of left atrium, with normalized left atrium (NLA) ≥10.25 [hazard ratios (HR) of 1.81, 95% confidence interval (CI): 1.28-2.56] when compared with NLA <10.25 (35% vs. 53%, P = 0.0001) and (2) renal function, with impaired glomerular filtration rate (GFR) <80 ml/min (HR of 1.26, 95% CI: 1.02-1.57) when compared with GFR ≥80 ml/min (45% vs. 53%, P = 0.041). Normalized left atrium ≥10.25 was the sole independent predictor for outcome (HR 2.11; 95% CI: 1.34-3.31; P = 0.0001).

CONCLUSIONS

Sinus rhythm can be maintained in a substantial proportion of patients with PAF even 5 years after circumferential PVI using CB ablation. The rate of decline in freedom from AFLAT was highest within the first 12 months after the index procedure. The patients with enlarged left atrium and/or impaired renal function have lower outcome.

Для цитирования: Neumann Thomas, Wójcik Maciej, Berkowitsch Alexander, Erkapic Damir, Zaltsberg Sergey, Greiss Harald, Pajitnev Dimitri, Lehinant Stefan, Schmitt Jörn, Hamm Christian W, Pitschner Heinz F, Kuniss Malte. Cryoballoon ablation of paroxysmal atrial fibrillation: 5-year outcome after single procedure and predictors of success.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2013. DOI: 10.1093/europace/eut021.