DOI 10.1136/bjophthalmol-2021-320621
Relationship of macular ganglion cell complex thickness to choroidal microvasculature drop-out in primary open-angle glaucoma.
Аннотация
BACKGROUND/AIMS: To investigate the rate of ganglion cell complex (GCC) thinning in primary open-angle glaucoma (POAG) patients with and without deep-layer microvasculature drop-out (MvD).
METHODS
POAG patients who had at least 1.5 years of follow-up and a minimum of three visits were included from the Diagnostic Innovations in Glaucoma Study. MvD was detected at baseline by optical coherence tomography angiography (OCT-A). Area and angular circumference of MvD were evaluated on en face choroidal vessel density images and horizontal B-scans. Rates of global and hemisphere GCC thinning were compared in MvD and non-MvD eyes using linear mixed-effects models.
RESULTS
Thirty-six eyes with MvD and 37 eyes without MvD of 63 patients were followed for a mean of 3.3 years. In 30 out of 36 eyes, MvD was localised in the inferotemporal region. While mean baseline visual field mean deviation was similar between the two groups (p=0.128), global GCC thinning was significantly faster in eyes with MvD than in those without MvD (mean differences: -0.50 (95% CI -0.83 to -0.17) µm/year; p=0.003)). Presence of MvD, area and angular circumference of MvD were independently associated with a faster rate of thinning (p=0.002, p=0.031 and p=0.013, respectively).
CONCLUSION
In POAG eyes, GCC thinning is faster in eyes with MvD. Detection of MvD in OCT-A images can assist clinicians to identify patients who are at higher risk for central macula thinning and glaucomatous progression and may require more intensive management.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.