m+Medelevator.RU
← Поиск публикаций
Photodiagnosis and photodynamic therapy · 2025

Optical fogging is an effective method of reducing overestimation of myopia.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lin Jiajia, Chen Ting, Lin Zequn, Xiong Xinyao, Chen Yinhe, Yu Yang, Huang Luoming

Аннотация

BACKGROUND: This study aimed to investigate the effectiveness of optical fogging in controlling accommodation and to evaluate its efficiency in reducing myopic overestimation among young adults, with the goal of providing scientific evidence for clinical refractive measurement.

METHODS: A total of 142 young adults aged 17 to 23 years (284 eyes) were enrolled. Refractive status and ocular biometric parameters were measured using open-field autorefractor and partial coherence interferometry under three conditions: baseline, optical fogging, and cycloplegia. Optical fogging was induced by wearing +2.00 D spherical lenses for 20 min, while cycloplegia was induced using 0.5 % compound tropicamide-phenylephrine eye drops. Eyes were categorized into overestimated and non-overestimated myopia groups based on whether the difference in spherical equivalent (SE) between cycloplegic and baseline measurements was ≥0.50 D. Changes in SE and lens thickness under the three conditions were analyzed, and the efficiency of optical fogging-induced accommodative control was calculated.

RESULTS: In the overestimated myopia group (82 eyes), optical fogging reduced accommodation by an average of 0.28 ± 0.37 D compared to baseline (p < 0.001), accounting for 36.84 % of the effect of cycloplegia (0.76 ± 0.29 D). In the total sample eyes, optical fogging reduced accommodation by 0.07 ± 0.34 D (p < 0.001), which corresponded to 21.88 % of the cycloplegic effect (0.32 ± 0.37 D). Lens thickness showed no significant change after optical fogging (all p > 0.05).

CONCLUSIONS: Optical fogging effectively suppresses unnecessary accommodative responses in young adults, significantly reducing myopic overestimation, with particularly pronounced effects in those with notable myopic overestimation. Although optical fogging is less effective than cycloplegia in relaxing accommodation, it offers advantages in terms of ease of use, non-invasiveness, and good tolerance, making it highly applicable in clinical refractive measurement.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты