X-ray tube operators can be exposed to equal or higher scattered radiation doses to the hand as cassette holders during diagnostic radiographic procedures of the equine vertebral column and limbs.

Belotta Alexandra F, Mayer Monique N, Waldner Cheryl L, Sidhu Narinder P, Robinson Kate A, Carmalt James L, Freitas Fernando P, Koehncke Niels K

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The objectives of this study were to investigate scattered radiation doses to the hands of equine workers holding the cassette and the x-ray tube by hand, for both limb and vertebral column studies, and to compare the scattered radiation attenuation of lead with radiation protection lead-free gloves. Radiation doses to the hands of the cassette holder in the primary beam were also investigated.

SAMPLE: A whole-body horse cadaver.

PROCEDURES: A portable x-ray unit was used to simulate 6 radiographic study types in the horse cadaver. Doses were measured with no shielding and, for cassette holders, with the ion chamber enclosed in a lead glove and a lead-free glove. Thirty exposures were performed for each study view and condition (n = 1,920).

RESULTS

Mean scattered doses to x-ray unit operators were higher than doses to cassette holders for ungula (hoof), thoracic vertebrae, and lumbar vertebrae studies, whereas doses to cassette holders were higher than doses to x-ray tube operators for studies of the metacarpophalangeal joint (fetlock) and tarsus (hock). Doses did not differ for the stifle joint. Mean percentage decrease in scattered radiation dose was 99.58% with lead gloves and 98.9% with lead-free gloves.

CLINICAL RELEVANCE: X-ray tube operators can be exposed to equal or higher scattered radiation doses to the hand as cassette holders. Lead-free hand shielding should only be considered as an alternative to lead gloves if their lighter weight increases frequency of use by workers.

Для цитирования: Belotta Alexandra F, Mayer Monique N, Waldner Cheryl L, Sidhu Narinder P, Robinson Kate A, Carmalt James L, Freitas Fernando P, Koehncke Niels K. X-ray tube operators can be exposed to equal or higher scattered radiation doses to the hand as cassette holders during diagnostic radiographic procedures of the equine vertebral column and limbs.. American journal of veterinary research. 2022. DOI: 10.2460/ajvr.21.08.0134.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.