Sealing Zone Failure Decreases the Long Term Durability of Endovascular Aneurysm Repair.

Sandström Charlotte, Andersson Mattias B, Bogdanovic Marko, Fattahi Nina, Lundqvist Robert, Andersson Manne, Roy Joy, Hultgren Rebecka, Roos Håkan

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Endovascular aneurysm repair (EVAR) has a higher long term aneurysm related mortality rate compared with open surgery, mainly due to aneurysm rupture. Loss of stent graft to vessel apposition at the EVAR sealing zones is a potential cause of post-EVAR rupture. This study aimed to investigate sealing zone failure and its relationship with post-EVAR rupture.

METHODS

This was a retrospective structured review of pre- and post-operative computed tomography (CT) scans of 399 consecutive patients treated with standard bifurcated EVAR. The primary outcome was total loss of seal at last post-operative CT. Secondary outcomes were partial loss of seal, standard follow up detection, post-EVAR rupture, aneurysm sac development, and endoleaks.

RESULTS

During a median follow up of 5.3 years, total and partial loss of seal occurred in 85 (21.3%) and 78 (19.5%) patients, respectively. Initial mean sealing zone lengths were within current recommendations but decreased over time, mainly due to vessel dilatation. Mean proximal sealing length at the one month CT was 15.5 ± 10.5 mm (95% confidence interval [CI] 12.6 - 18.5 mm) in the group with total loss of seal, 14.3 ± 6.9 mm (95% CI 12.2 - 16.4 mm) with partial loss of seal, and 23.2 ± 7.4 mm (95% CI 22.3 - 24.0 mm) with preserved seal through follow up (p < .001). Mean iliac sealing lengths were 22.4 ± 12.1 mm (95% CI 18.9 - 25.8 mm) if total loss and 21.8 ± 10.0 mm (95% CI 19.6 - 24.0 mm) if partial loss of seal vs. 34.7 ± 12.4 mm (95% CI 33.8 - 35.7 mm) if preserved seal. Larger vessel diameters were associated with loss of seal in both the proximal and distal sealing zones. During the study period, 13 post-EVAR ruptures occurred, all preceded by CT findings of total (n = 7) or partial (n = 6) loss of seal. Aneurysm sac expansion was seen in 40% of patients with total loss of seal, 18% with partial loss of seal, and 6.6% with preserved seal.

CONCLUSION

Loss of seal after EVAR is frequent and associated with post-EVAR rupture. Increased recommended sealing zones lengths and focus on sealing zones in surveillance may reduce post-EVAR ruptures and aneurysm related death.

Для цитирования: Sandström Charlotte, Andersson Mattias B, Bogdanovic Marko, Fattahi Nina, Lundqvist Robert, Andersson Manne, Roy Joy, Hultgren Rebecka, Roos Håkan. Sealing Zone Failure Decreases the Long Term Durability of Endovascular Aneurysm Repair.. European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery. 2024. DOI: 10.1016/j.ejvs.2024.09.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.