DOI 10.1111/j.1748-1716.2008.01883.x
Correlations between clinical and physiological consequences of the novel mutation R878C in a highly conserved pore residue in the cardiac Na+ channel.
Аннотация
AIM: We compared the clinical and physiological consequences of the novel mutation R878C in a highly conserved pore residue in domain II (S5-S6) of human, hNa(v)1.5, cardiac Na(+) channels.
METHODS
Full clinical evaluation of pedigree members through three generations of a Chinese family combined with SCN5A sequencing from genomic DNA was compared with patch and voltage-clamp results from two independent expression systems.
RESULTS
The four mutation carriers showed bradycardia, and slowed sino-atrial, atrioventricular and intraventricular conduction. Two also showed sick sinus syndrome; two had ST elevation in leads V1 and V2. Unlike WT-hNa(v)1.5, whole-cell patch-clamped HEK293 cells expressing R878C-hNa(v)1.5 showed no detectable Na(+) currents (i(Na)), even with substitution of a similarly charged lysine residue. Voltage-clamped Xenopus oocytes injected with either 0.04 or 1.5 microg microL(-1) R878C-hNa(v)1.5 cRNA similarly showed no i(Na), yet WT-hNa(v)1.5 cRNA diluted to 0.0004-0.0008 ng microL(-1)resulted in expression of detectable i(Na). i(Na) was simply determined by the amount of injected WT-hNa(v)1.5: doubling the dose of WT-hNa(v)1.5 cRNA doubled i(Na). i(Na) amplitudes and activation and inactivation characteristics were similar irrespective of whether WT-hNa(v)1.5 cRNA was given alone or combined with equal doses of R878C-hNa(v)1.5 cRNA therefore excluding dominant negative phenotypic effects. Na(+) channel function in HEK293 cells transfected with R878C-hNa(v)1.5 was not restored by exposure to mexiletine (200 microM) and lidocaine (100 microM). Fluorescence confocal microscopy using E3-Nav1.5 antibody demonstrated persistent membrane expression of both WT and R878C-hNa(v)1.5. Modelling studies confirmed that such i(Na) reductions reproduced the SSS phenotype.
CONCLUSION
Clinical consequences of the novel R878C mutation correlate with results of physiological studies.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.