Genetic and Clinical Features of ABCA4-Associated Retinopathy in a Japanese Nationwide Cohort.
Аннотация
PURPOSE: To clarify the genetic and clinical features of Japanese patients with ABCA4-associated retinopathy.
DESIGN
Retrospective, multicenter cohort study.
METHODS
Patients with retinal degeneration and biallelic ABCA4 variants were recruited from 13 different hospitals. Whole exome sequencing analysis was used for genetic testing. Comprehensive ophthalmic examinations were performed on matched patients. The primary outcome measure was identifying multimodal retinal imaging findings associated with disease progression.
RESULTS
This study included 63 patients: 19 with missense/missense, 23 with missense/truncation, and 21 with truncation/truncation genotypes. In total, 62 variants were identified, including 29 novel variants. Six patients had a mild phenotype characterized by foveal-sparing or preserved foveal structure, including 4 with missense/missense and 2 with missense/truncation genotypes. The p.Arg212His variant was the most frequent in patients with mild phenotypes (4/12 alleles). Clinical findings showed a disease duration-dependent worsening of the phenotypic stage. Patients with the truncation/truncation genotype exhibited rapid retinal degeneration within a few years and definite fundus autofluorescence imaging patterns, including hyper autofluorescence at the macula and few or no flecks.
CONCLUSIONS
Our results indicate that missense/missense or missense/truncation genotypes, including the p.Arg212His variant, are associated with a relatively mild phenotype. In contrast, the truncation/truncation genotype causes rapid and severe retinal degeneration in Japanese patients with ABCA4-associated retinopathy. These data are vital in predicting patient prognosis, guiding genetic counseling, and stratifying patients for future clinical trials.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.