BACKGROUND

ABO major compatibility is essential in transfusions of red blood cells but is not requisite in PLT transfusions. In adults there is some evidence that transfusion efficacy of ABO blood group-identical platelets (PLTs) is superior to major-mismatched PLTs. However, in children this question has not been investigated for more than 30 years.

STUDY DESIGN AND

METHODS

In a prospective study, the efficacy (based on the 1-hour percentage of PLT recovery [PPR(1hr)]) of 400 eligible ABO blood group-identical or out-of-group apheresis PLT concentrates (APCs), transfused mainly prophylactically to 50 children with hematologic malignancies, solid tumors, or aplastic anemia was investigated. The primary objective was to compare PPR(1hr) between ABO-identical and major-mismatched transfusions.

RESULTS

After ABO major-mismatched transfusions, PPR(1hr) was significantly lower than after ABO blood group-identical transfusions (median 21% vs. 32%; p = 0.034). Multivariate analysis showed major-mismatched transfusions to be significantly more often unsuccessful than identical transfusions (odds ratio [OR], 3.97; 95% confidence interval [CI], 1.52-10.39; p = 0.005). Using flow cytometry and fluorescent microscopy, it could be demonstrated that PLTs of subgroup A(1), significantly expressing A antigen on their surface, were rapidly cleared from the circulation of group O or B recipients. In contrast, major-mismatched transfusions of A(2) PLTs, expressing no detectable A antigen, were as successful as identical transfusions (OR, 1.13; 95% CI, 0.16-7.88; p = 0.90).

CONCLUSION

These data clearly indicate that in children ABO major-mismatched PLT transfusions result in inferior transfusion efficacy, with the only exception of group A(2) PLTs. ABO minor-mismatched PLTs showed comparable efficacy to identical transfusions.

Для цитирования: Julmy Friedgard, Ammann Roland A, Taleghani Behrouz Mansouri, Fontana Stefano, Hirt Andreas, Leibundgut Kurt. Transfusion efficacy of ABO major-mismatched platelets (PLTs) in children is inferior to that of ABO-identical PLTs.. Transfusion. 2008. DOI: 10.1111/j.1537-2995.2008.01914.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.