MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1537-2995.2007.01283.x

Медицинская библиотека · Transfusion · 2007

Nonfatal intravascular hemolysis in a pediatric patient after transfusion of a platelet unit with high-titer anti-A.

Harris Shealynn B, Josephson Cassandra D, Kost Christine B, Hillyer Christopher D

Клинический случайСтатьяОбзорПеревод пока не подготовлен

Аннотация

BACKGROUND

In the pediatric population, hemolysis after out-of-group platelet (PLT) transfusion is a potentially fatal event that is thought to be underrecognized. Group A patients transfused with group O single-donor PLTs (SDPs) with "high-titer" anti-A are at greatest risk for hemolysis.

STUDY DESIGN AND

METHODS

A clinical and serologic evaluation of a pediatric patient with hemolysis of initially unknown etiology was conducted. Retrospective testing for anti-A titer of an admission sample and a transfused group O SDP was performed.

RESULTS

The group A patient (previously group O) was found to have a history of engrafted major ABO-mismatched hematopoietic peripheral blood progenitor cell transplant (HPBPCT). Immune-mediated intravascular hemolysis with a delayed presentation was determined. Testing identified passive anti-A in the patient's plasma and high-titer anti-A (IgG 4096, IgM 256) in the group O SDP unit.

CONCLUSION

Hemolysis after out-of-group SDP transfusion may be delayed in presentation and, thus, clinically unrecognized. When evaluating these cases, the limitations of routine type and screen for detection of passive anti-A must be considered. Group A individuals with a history of engrafted major ABO-mismatched HPBPCT potentially have increased susceptibility to hemolysis from group O SDP transfusion due to their lack of tissue and soluble A antigen.

Для цитирования: Harris Shealynn B, Josephson Cassandra D, Kost Christine B, Hillyer Christopher D. Nonfatal intravascular hemolysis in a pediatric patient after transfusion of a platelet unit with high-titer anti-A.. Transfusion. 2007. DOI: 10.1111/j.1537-2995.2007.01283.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.