Real-time and Doppler US after pediatric segmental liver transplantation : I. Portal vein stenosis.
Аннотация
BACKGROUND
Accurate diagnosis of portal vein (PV) stenosis by real-time and color Doppler US (CD-US) after segmental liver transplantation in children can decrease morbidity by avoiding unnecessary biopsy, PV hypertension, thrombosis and loss of the graft.
OBJECTIVE
To evaluate CD-US parameters for the prediction of PV stenosis after segmental liver transplantation in children.
MATERIALS AND
METHODS
We retrospectively reviewed 61 CD-US examinations measuring the diameter at the PV anastomosis, velocities at the anastomosis (PV1) and in the segment proximal to the anastomosis (PV2), and the PV1/PV2 velocity ratio. The study group comprised patients with stenosis confirmed by angiography and the control group comprised patients with a good clinical outcome.
RESULTS
PV stenosis was seen in 12 CD-US examinations. The mean PV diameter was smaller in the study group (2.6 mm versus 5.7 mm) and a PV diameter of <3.5 mm was highly predictive of stenosis (sensitivity 100%, specificity 91.8%).
CONCLUSION
A PV diameter of <3.5 mm is a highly predictive CD-US parameter for the detection of hemodynamically significant stenosis on angiography.