MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00005373-198805000-00002

Медицинская библиотека · The Journal of trauma · 1988

Effect of fibronectin-rich human cryoprecipitate on fluid volume requirements in sheep during postoperative sepsis.

Holman J M, Saba T M, Lewis E

СтатьяПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

Septic surgical patients often require fluid administration to maintain cardiovascular stability due, in part, to the sepsis-induced increase in vascular permeability and associated plasma volume depletion. Plasma fibronectin deficiency exists in such septic patients. We determined if maintenance of fibronectin levels by administration of fibronectin-rich human plasma cryoprecipitate would lower the resuscitative fluid volume needed for support of arterial pressure in septic postoperative sheep which were experimentally depleted of plasma fibronectin. Following a 2-hr postoperative baseline period, denatured collagen (gelatin, 8.7 mg/kg), which has a high affinity for fibronectin, was infused into both control and experimental sheep in order to acutely deplete plasma fibronectin. Sheep were then challenged both intraperitoneally and intravenously with live Pseudomonas (5 x 10(10) bacteria IP; 5 x 10(9) bacteria IV). Experimentals were given fresh plasma cryoprecipitate intravenously at a dose of 4 units bolus, followed by 3 units/hr for 5 hr. Controls received plasma cryoprecipitate selectively depleted of fibronectin by affinity chromatography. Bacterial challenge rapidly resulted in severe systemic hypotension. Ringer's lactate was infused intravenously into both groups at a rate sufficient to maintain a systemic arterial pressure of approximately 50 mm Hg with a maximum pulmonary artery wedge pressure of 15-18 mm Hg. Its rate of infusion was periodically adjusted to maintain this hemodynamic status. Comparison was made of the volume of Ringer's lactate required to maintain an arterial pressure of 50 mm Hg in both groups. Net fluid requirement was significantly (p less than 0.05) less in postoperative septic sheep (47.4 +/- 6.2 mg/kg/hr) treated with fibronectin-rich cryoprecipitate compared to the fluid requirement (71.7 +/- 4.7 mg/kg/hr) for postoperative septic sheep receiving fibronectin-deficient cryoprecipitate. Thus elevation of plasma fibronectin concentration lowers the fluid requirements needed for hemodynamic support in postoperative Gram-negative sepsis.

Для цитирования: Holman J M, Saba T M, Lewis E. Effect of fibronectin-rich human cryoprecipitate on fluid volume requirements in sheep during postoperative sepsis.. The Journal of trauma. 1988. DOI: 10.1097/00005373-198805000-00002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.