OBJECTIVES
As point-of-care ultrasound (POCUS) has emerged as a valuable tool for intussusception screening, this quality improvement study aimed to implement a "POCUS-first" pathway in a Pediatric Emergency Department (ED) to streamline workflow and expedite care for children with suspected intussusception.
METHODS
This was a prospective analysis of children diagnosed with ileocolic intussusception in a Pediatric ED between June 2022 and June 2023. The study compared the "POCUS-first" cohort with the group receiving only radiology-performed ultrasound. Key outcomes included physician initial assessment to radiology-performed US time and physician initial assessment to reduction time. Continuous improvement efforts incorporated pediatric emergency medicine physician training, education, and pathway dissemination through plan-do-study-act cycles.
RESULTS
The study included 29 patients in the "POCUS-first" pathway group and 70 patients in the non-POCUS group. The "POCUS-first" pathway demonstrated a significantly shorter physician initial assessment to reduction time compared to the non-POCUS group (170.7 min vs. 240.6 min, p = 0.02). Among non-transferred patients, the "POCUS-first" group also had a significantly shorter emergency department length of stay (386 min vs. 544 min, p = 0.047).
CONCLUSIONS
Implementation of a "POCUS-first" pathway for managing ileocolic intussusception led to notable improvements in process efficiency. The shorter physician initial assessment to reduction time highlights the potential for expedited decision-making and intervention. These study findings support the potential of this pathway to optimize the management and outcomes of children with ileocolic intussusception.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.