Detection of H5 subtype avian influenza virus in avian oropharyngeal swab samples using a microfluidic non-competitive fluorescence polarization immunoassay.

Takahashi Kazuki, Takeda Yohei, Nishiyama Keine, Fukuyama Mao, Maeki Masatoshi, Ishida Akihiko, Tani Hirofumi, Imai Ayuko, Shigemura Koji, Hibara Akihide, Ogawa Haruko, Tokeshi Manabu

СтатьяПеревод пока не подготовлен

Аннотация

Rapid and simple methods for on-site detection of avian influenza virus (AIV) are essential for effective field surveillance. In this study, a microfluidic device-based non-competitive fluorescence polarization immunoassay (NC-FPIA) using an ATTO 647N-labeled hemagglutinin fragment of H5 subtype AIV (H5-AIV) as a tracer was developed for the quantification of H5-AIV in avian oropharyngeal swab samples. Autofluorescence from the swab matrix significantly interfered with fluorescence polarization measurements. However, quantitative detection of H5-AIV was achieved by suppressing the matrix effect through 80-fold dilution. The limit of detection was 186.4 μg mL-1. The assay can be completed within 20 minutes without complex sample preparation, making it suitable for rapid on-site applications, including field surveillance of AIV in wild birds and poultry. Furthermore, by designing appropriate tracers, the method can be extended to other AIV subtypes.

Для цитирования: Takahashi Kazuki, Takeda Yohei, Nishiyama Keine, Fukuyama Mao, Maeki Masatoshi, Ishida Akihiko, Tani Hirofumi, Imai Ayuko, Shigemura Koji, Hibara Akihide, Ogawa Haruko, Tokeshi Manabu. Detection of H5 subtype avian influenza virus in avian oropharyngeal swab samples using a microfluidic non-competitive fluorescence polarization immunoassay.. The Analyst. 2026. DOI: 10.1039/d6an00505e.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.