MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/icl.0000000000001048

Медицинская библиотека · Eye & contact lens · 2024

Exploring the Location of Corneal Pigmented Arc and Myopia Control Efficacy in Orthokeratology-Treated Children Using Pentacam Measurements.

Kuo Yu-Kai, Chuang Lan-Hsin, Lai Chi-Chun, Wu Pei-Chang, Chen Shin-Yi, Chen Hung-Chi, Yeung Ling, Wang Nan-Kai, Hwang Yih-Shiou, Liu Chun-Fu

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To determine the location and intensity of the corneal pigmented arc in orthokeratology (ortho-k)-treated children and its relationship with annual axial length (AL) change using Pentacam.

METHODS

This retrospective cohort study enrolled children aged 9 to 15 years who had been followed up for at least one year after ortho-k treatment for myopia control. A Pentacam was used to determine the location and intensity of pigmented arc after lens wear. Annual AL changes were further used as the outcome measurement to determine their relationships with the location and intensity of pigmented arc using generalized estimating equations (GEE).

RESULTS

In total, 62 eyes from 33 patients (mean age 10.9 years) were included in our final analysis. The mean follow-up time was 30.6 months. The mean annual AL changes were 0.10 mm. Age statistically correlated with annual AL change (GEE, P= 0.033). In addition, the annual AL change was negatively associated with the relative vertical distance of the lowest density of pigmented arc point based on the visual center, pupil center, and corneal thinnest point after adjustment with age ( P =0.005, P =0.004, and P< 0.001, respectively).

CONCLUSIONS

Pentacam could be a useful tool for evaluating the location and intensity of the corneal pigmented arc. In addition, there was a negative correlation between the vertical distance of the pigmented arc and annual AL change. These findings may provide important information regarding myopia control, next-generation ortho-k design, and prescription.

Для цитирования: Kuo Yu-Kai, Chuang Lan-Hsin, Lai Chi-Chun, Wu Pei-Chang, Chen Shin-Yi, Chen Hung-Chi, Yeung Ling, Wang Nan-Kai, Hwang Yih-Shiou, Liu Chun-Fu. Exploring the Location of Corneal Pigmented Arc and Myopia Control Efficacy in Orthokeratology-Treated Children Using Pentacam Measurements.. Eye & contact lens. 2024. DOI: 10.1097/icl.0000000000001048.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.