MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jum.16757

Медицинская библиотека · Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2025

The Influence of Probe Pressure on Appendix Visualization in Pediatric Sonography: A Pilot Study.

Ahyad Rayan A

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To investigate the influence of ultrasound probe pressure on the visualization of the appendix sonographically.

METHODS

Pediatric outpatients undergoing routine renal ultrasound (US) were approached for additional images using a standardized imaging protocol. The movement of the normal appendix (base and distal parts) was documented while applying probe pressure. The minimum pressure required for appendix identification and the maximum pressure required to elicit movement out of the field-of-view were recorded using a force sensor. Skin thickness was measured at baseline, at first appendix identification, and at maximal pressure. Appendiceal locations and peri-appendicular findings were also recorded.

RESULTS

Forty-six US scans were included in the final analysis. The appendix was identified in all scans. Movement out of the field-of-view was documented in 30 scans, of which 12 showed movement of the entire appendix, 11 of the distal appendix, and seven of the appendicular base only. The mean pressure was lower when the appendix was identified than when its base and distal part moved out of the field-of-view. The mean skin thickness was comparable. Neither pressure nor skin thickness showed a statistically significant correlation with appendix movement out of the field-of-view.

CONCLUSIONS

Despite no statistically significant correlation between the applied pressure and the appendiceal movement, since all the appendices were identified with less pressure than the pressure needed to displace most of them out of the field-of-view, it is possible that the non-visualization of the appendix is attributed to the displacement of the organ due to excessive sonographic pressure.

Для цитирования: Ahyad Rayan A. The Influence of Probe Pressure on Appendix Visualization in Pediatric Sonography: A Pilot Study.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2025. DOI: 10.1002/jum.16757.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.