Post-operative use of heparin increases morbidity of pacemaker implantation.

Marquie C, De Geeter G, Klug D, Kouakam C, Brigadeau F, Jabourek O, Trillot N, Lacroix D, Kacet S

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: The objective of this study is to characterize the incidence of peri-operative severe adverse events (AEs) related to the post-operative use of heparin in patients undergoing pacemaker surgery.

METHODS AND

RESULTS

We retrospectively compared the outcome of 38 patients with mechanical valves (MVs) and 76 patients with atrial fibrillation (AF) with control cases matched for gender, age, and surgical details. Heparin was systematically used post-operatively in MV patients, but left to clinical judgment in AF patients. The relative risk for severe haemorrhagic AEs was 11 (CI 1.5-81.1, P < 0.01) in the MV group when compared with matched controls and 8 (CI 1.0-62.5, P < 0.05) in the AF group. Overall, the relative risk of heparin use in the post-operative period was 14 (CI 1.88-104, P = 0.0006) and the post-operative stay was prolonged from 7 days in this group when compared with control cases (P < 0.0001).The variables associated with haemorrhage were the delay to restart heparin after surgery and the presence of an MV.

CONCLUSION

Post-operative use of heparin increases morbidity of pacemaker implantation. A different approach to management of these patients is possible.

Для цитирования: Marquie C, De Geeter G, Klug D, Kouakam C, Brigadeau F, Jabourek O, Trillot N, Lacroix D, Kacet S. Post-operative use of heparin increases morbidity of pacemaker implantation.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2006. DOI: 10.1093/europace/eul011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.