MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/13872877241304607

Медицинская библиотека · Journal of Alzheimer's disease : JAD · 2025

Clinical validation of artificial intelligence-based single-subject morphometry without normative reference database.

Hedderich Dennis M, Opfer Roland, Krüger Julia, Spies Lothar, Yakushev Igor, Buchert Ralph

СтатьяВалидационное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Single-subject voxel-based morphometry (VBM) is a powerful technique for reader-independent detection of brain atrophy in structural magnetic resonance imaging (MRI) to support the (differential) diagnosis and staging of neurodegenerative diseases in individual patients. However, VBM is sensitive to the MRI scanner platform and details of the acquisition sequence. To mitigate this limitation, we recently proposed and technically validated a convolutional neural network (CNN)-based VBM which does not rely on a normative reference database.

OBJECTIVE

Clinical validation of CNN-based VBM.

METHODS

CNN-based VBM was compared with conventional VBM based on a mixed-scanner normative database in 227 consecutive patients (66.0 ± 9.6 years, 53.3% female) with suspected dementing neurodegenerative disease. VBM maps were interpreted visually by two experienced readers, first with respect to the presence of any neurodegenerative disease, then for the differentiation between Alzheimer's disease (AD)-typical and non-AD atrophy patterns. A Likert 6-score was used for both tasks. Simultaneously acquired positron emission tomography (PET) with 18F-fluorodeoxyglucose (FDG) served as reference standard.

RESULTS

Repeated-measures ANOVA revealed a significant impact of the VBM method on the visual detection of any neurodegenerative disease (p < 0.001). Balanced accuracy/sensitivity/specificity were 80.4/86.3/74.5% for CNN-based VBM versus 75.7/79.5/71.8% for conventional VBM. Differentiation between AD and non-AD typical atrophy patterns did not differ between both VBM methods (p = 0.871).

CONCLUSIONS

CNN-based VBM provides clinically useful accuracy for the detection of neurodegeneration-suspect atrophy with higher sensitivity than conventional VBM with a mixed-scanner normative reference database and without compromising specificity.

Для цитирования: Hedderich Dennis M, Opfer Roland, Krüger Julia, Spies Lothar, Yakushev Igor, Buchert Ralph. Clinical validation of artificial intelligence-based single-subject morphometry without normative reference database.. Journal of Alzheimer's disease : JAD. 2025. DOI: 10.1177/13872877241304607.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.