Shyn Paul B, Seyal Adeel R, Gottumukkala Ravi V, Silverman Stuart G, Bhagavatula Sharath K, Alencar Raquel O, Dabiri Borna E, Souza Daniel A T, Cosman Eric R, Kapur Tina

Аннотация

PURPOSE: The purpose of this study was to assess the feasibility and safety of using a bipolar radiofrequency track cautery device during percutaneous image-guided abdominal biopsy procedures in at-risk patients.

METHODS: Forty-two patients (26-79 years old; female 44%) with at least one bleeding risk factor who underwent an abdominal image-guided (CT or US) biopsy and intended bipolar radiofrequency track cautery (BRTC) were retrospectively studied. An 18G radiofrequency electrode was inserted through a 17G biopsy introducer needle immediately following coaxial 18G core biopsy, to cauterize the biopsy track using temperature control. Bleeding risk factors, technical success, and adverse events were recorded.

RESULTS: BRTC was technically successful in 41/42 (98%) of procedures; in one patient, the introducer needle retracted from the liver due to respiratory motion prior to BRTC. BRTC following percutaneous biopsy was applied during 41 abdominal biopsy procedures (renal mass = 12, renal parenchyma = 10, liver mass = 9, liver parenchyma = 5, splenic mass or parenchyma = 4, gastrohepatic mass = 1). All patients had one or more of the following risk factors: high-risk organ (spleen or renal parenchyma), hypervascular mass, elevated prothrombin time, renal insufficiency, thrombocytopenia, recent anticoagulation or anticoagulation not withheld for recommended interval, cirrhosis, intraprocedural hypertension, brisk back bleeding observed from the introducer needle, or subcapsular tumor location. No severe adverse events (grade 3 or higher) occurred. Two (2/41, 5%) mild (grade 1) bleeding events did not cause symptoms or require intervention.

CONCLUSION: Bipolar radiofrequency track cautery was feasible and safe during percutaneous image-guided abdominal biopsy procedures. IRB approval: MBG 2022P002277.