Thrombosis and haemostasis · 2014
Antibody-based prevention of von Willebrand factor degradation mediated by circulatory assist devices.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Rauch Antoine, Legendre Paulette, Christophe Olivier D, Goudemand Jenny, van Belle Eric, Vincentelli André, Denis Cécile V, Susen Sophie, Lenting Peter J
Аннотация
Haemorrhagic episodes in patients carrying circulatory assist devices represent a severe life-threatening clinical complication. These bleeding episodes may originate from a reduced functionality of von Willebrand factor (VWF), a multimeric protein pertinent to the formation of a haemostatic plug. It has been reported that the reduced functionality is due to increased proteolytic degradation by the enzyme ADAMTS13, a phenomenon that is facilitated by device-induced increases in shear stress to which VWF is exposed. Here, we have tested a series of VWF-derived protein fragments and monoclonal murine anti-VWF antibodies for their capacity to reduce shear stress-dependent degradation of VWF. Via direct binding experiments, we identified an anti-VWF antibody that partially blocked VWF-ADAMTS13 interactions (46 ± 14%). Epitope mapping experiments revealed that the antibody, designated mAb508, is directed against the distal portion of the VWF D4-domain (residues 2134-2301) and recognises a synthetic peptide encompassing residues 2158-2169. Consistent with its partial inhibition of VWF-ADAMTS13 interactions in binding assays, mAb508 reduced ADAMTS13-mediated VWF degradation in a vortex-based degradation assay by 48 ± 10%. In a HeartMateII-based whole blood-perfusion system, mAb508 was able to reduce degradation of high-molecular-weight (HMW)-VWF-multimers dose-dependently, with a maximal inhibition (83 ± 8%) being reached at concentrations of 10 μg/ml or higher. In conclusion, we report that partial inhibition of VWF-ADAMTS13 interactions using an anti-VWF antibody can prevent excessive degradation of HMW-VWF multimers. This strategy may be used for the development of therapeutic options to treat bleeding episodes due to shear stress-dependent VWF degradation, for instance in patients carrying circulatory assist devices.