MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10840-015-0015-3

Медицинская библиотека · Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2015

Impact of cardiac resynchronization therapy-defibrillator implantation on the association between body mass index and prognosis in patients with heart failure.

Yanagisawa Satoshi, Inden Yasuya, Shimano Masayuki, Yoshida Naoki, Ishikawa Shinji, Kato Hiroyuki, Okumura Satoshi, Miyoshi-Fujii Aya, Nagao Tomoyuki, Yamamoto Toshihiko, Mizutani Yoshiaki, Ito Tadahiro, Hirai Makoto, Murohara Toyoaki

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: This study aimed to examine the association between body mass index (BMI) and prognosis in heart failure patients after cardiac resynchronization therapy-defibrillator (CRT-D) implantation.

METHODS

We retrospectively investigated 125 patients (33 overweight [BMI ≥25 kg/m(2)], 75 normal weight [BMI 18.5-24.9 kg/m(2)], and 17 underweight patients [BMI <18.5 kg/m(2)]) who underwent CRT-D implantation. The clinical outcome endpoints were all-cause death and appropriate shock therapy.

RESULTS

During the follow-up period (mean 3.1 ± 1.8 years), 23 patients died (1 [3.0 %] overweight, 17 [22.7 %] normal weight, and 5 [29.4 %] underweight patients), and appropriate shock events were observed in 14 patients (2 [6.1 %] overweight, 10 [13.3 %] normal weight, and 2 [11.8 %] underweight patients). All patients survived shock therapy. After adjusting for confounding factors, overweight patients had significantly fewer outcomes relating to all-cause death and appropriate shock events (hazard ratio 0.27, 95 % confidence interval 0.08-0.91, p = 0.034) than normal weight patients. However, the prognostic difference between overweight and normal weight patients could be diminished as a result of the successful shock therapies (p = 0.067). Additionally, prognosis did not differ between overweight and normal weight patients among the responders, but did differ among the non-responders. The underweight patients had a poorer prognosis after CRT-D implantation compared with the other groups.

CONCLUSIONS

Although high BMI was associated with better outcomes among heart failure patients with CRT-D implantations, the difference in the prognosis between overweight and normal weight patients was reduced because of defibrillator therapy and the improvement in cardiac function provided by CRT-D implantation.

Для цитирования: Yanagisawa Satoshi, Inden Yasuya, Shimano Masayuki, Yoshida Naoki, Ishikawa Shinji, Kato Hiroyuki, Okumura Satoshi, Miyoshi-Fujii Aya, Nagao Tomoyuki, Yamamoto Toshihiko, Mizutani Yoshiaki, Ito Tadahiro, Hirai Makoto, Murohara Toyoaki. Impact of cardiac resynchronization therapy-defibrillator implantation on the association between body mass index and prognosis in patients with heart failure.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2015. DOI: 10.1007/s10840-015-0015-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.