m+Medelevator.RU
← Поиск публикаций
Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases · 2024

Dextrose-containing fluids causing false-positive serum galactomannan: a case-control study and interrupted time series analysis.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lee Raeseok, Yoo In Young, Oh Eun-Jee, Choi Ae Ran, Nho Dukhee, Cho Sung-Yeon, Lee Jongin, Ahn Hye Lim, Park Yeon-Joon, Lee Dong-Gun

Аннотация

OBJECTIVES: This study aimed to identify the cause of false-positive serum Aspergillus antigen galactomannan (GM) results in our centre.

METHODS: We performed a case-control study aiming to elucidate the factors associated with false-positive GM results. Independent risk factors for false-positive GM were evaluated through a multivariable regression analysis. An interrupted time series analysis was used to evaluate the effectiveness of an intervention removing the identified factors.

RESULTS: Among 568 patients tested, GM was positive in 130 patients of whom 97 had false-positive GM (cases). These were compared with 427 patients with true-negative GM (controls). Administration of dextrose-containing fluids within 6 days before GM testing was an independent predictor for false-positive GM results (adjusted odds ratio [aOR], 18.60; 95% CI, 8.95-38.66. An analysis of GM presence in different dextrose-containing fluids revealed positivity in 34.8% (8 of 23) (manufacturer A) and 33.3% (5 of 15) (manufacturer B) of the samples. Investigation of the manufacturing process revealed that the saccharification process employed enzymes derived from Aspergillus niger. After identifying the root cause of false positivity, GM-containing dextrose fluid use was restricted. Interrupted time series analysis showed an immediate reduction of GM false-positivity (-6.5% per week, p = 0.045) and a declining trend (-0.33% per week, p = 0.005) postintervention.

CONCLUSIONS: Administering dextrose-containing fluids was the primary factor causing false-positive serum Aspergillus antigen GM assay results. Our investigation led to a modification of the manufacturing process of the dextrose-containing fluids.