MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpurol.2021.05.002

Медицинская библиотека · Journal of pediatric urology · 2021

Totally robotic intracorporeal Monti-Yang continent ileovesicostomy in patient with previous robotic surgery-Technique description.

Galvez Cinthia, Lopategui Diana M, Horodyski Laura, Castellan Miguel

Клинический случайСтатьяVideo-Audio MediaПеревод пока не подготовлен

Аннотация

We present a video case report of a pediatric patient with previous robotic abdominal surgery who underwent robotic assisted Monti-Yang continent ileovesicostomy. This 10-year-old female had a history of spina bifida, with previous myelomeningocele repair and ventriculoperitoneal shunt as an infant and robotic-assisted Malone procedure and artificial urethral sphincter placed 4 years ago. After undergoing bilateral hip surgery, she presented with difficult urethral catheterization due to reduced leg mobility. A Monti-Yang ileovesicostomy procedure was planned. A 5 mm laparoscopic port placed through the umbilicus followed by four additional DaVinci XI working ports. Twenty centimeters proximal the ileocecal valve, a 3 cm segment of ileum was dissected, then transected, detubularized, and retubularized around a 10 Fr catheter. This conduit was reimplanted to the anterior bladder wall. The other edge was fixed to the umbilicus. A 10 Fr Foley catheter was left clamped in the conduit, and a urethral Foley was left to gravity. Total operative time was 3 h 56 min. The patient did well post-operatively. She was discharged home on POD 6. Starting three weeks after surgery, the patient began catheterizing through the umbilical stoma. At 3 month follow-up, the patient catheterizes through her stoma every 3 h without leakage between catheterizations.

Для цитирования: Galvez Cinthia, Lopategui Diana M, Horodyski Laura, Castellan Miguel. Totally robotic intracorporeal Monti-Yang continent ileovesicostomy in patient with previous robotic surgery-Technique description.. Journal of pediatric urology. 2021. DOI: 10.1016/j.jpurol.2021.05.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.