Feasibility of intrasurgical spectral-domain optical coherence tomography.

Binder Susanne, Falkner-Radler Christiane I, Hauger Christoph, Matz Holger, Glittenberg Carl

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the feasibility of intrasurgical spectral-domain optical coherence tomography in a pilot study.

METHODS

Using a Carl Zeiss Meditec Cirrus HD-OCT system adapted to the optical pathway of a Zeiss OPMI VISU 200 surgical microscope, 512 × 128 macular cube scans were performed during various steps of microsurgical procedures in 25 cases. The acquired volume data were postprocessed and visualized using a ray-traced three-dimensional display system.

RESULTS

The surgical procedures included pars plana vitrectomies for epiretinal membranes (n = 8), macular holes (n = 4), primary rhegmatogenous retinal detachment (n = 1), proliferative diabetic retinopathy (n = 3), silicone oil removal (n = 2), and cataract surgery only (n = 7). It was possible to acquire intraretinal scans with sufficient quality from all patients. Decisions for additional membrane peeling, knowledge about the behavior of the macular hole and the foveal depression during and after membrane removal, information about clinically invisible fluid accumulation under silicone oil or in a clinically diagnosed "macula-on" retinal detachment, and the condition of the fovea immediately after cataract removal could be gained.

CONCLUSION

Intrasurgical spectral-domain optical coherence tomography evaluation is feasible using the tested system and may positively influence surgical decisions and techniques resulting in an improved patient outcome.

Для цитирования: Binder Susanne, Falkner-Radler Christiane I, Hauger Christoph, Matz Holger, Glittenberg Carl. Feasibility of intrasurgical spectral-domain optical coherence tomography.. Retina (Philadelphia, Pa.). 2011. DOI: 10.1097/iae.0b013e3182019c18.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.