MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clinbiochem.2021.01.009

Медицинская библиотека · Clinical biochemistry · 2021

Orexin-A measurement in narcolepsy: A stability study and a comparison of LC-MS/MS and immunoassays.

Lindström Mikael, Schinkelshoek Mink, Tienari Pentti J, Kukkonen Jyrki P, Renkonen Risto, Fronczek Rolf, Lammers Gert Jan, Itkonen Outi

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Orexin-A and -B are neuropeptides involved in sleep-wake regulation. In human narcolepsy type 1, this cycle is disrupted due to loss of orexin-producing neurons in the hypothalamus. Cerebrospinal fluid (CSF) orexin-A measurement is used in the diagnosis of narcolepsy type 1. Currently available immunoassays may lack specificity for accurate orexin quantification. We developed and validated a liquid chromatography mass spectrometry assay (LC-MS/MS) for CSF orexin-A and B.

METHODS

We used CSF samples from narcolepsy type 1 (n = 22) and type 2 (n = 6) and non-narcoleptic controls (n = 44). Stable isotope-labeled orexin-A and -B internal standards were added to samples before solid-phase extraction and quantification by LC-MS/MS. The samples were also assayed by commercial radioimmunoassay (RIA, n = 42) and enzymatic immunoassay (EIA, n = 72) kits. Stability of orexins in CSF was studied for 12 months.

RESULTS

Our assay has a good sensitivity (10 pmol/L = 35 pg/mL) and a wide linear range (35-3500 pg/mL). Added orexin-A and -B were stable in CSF for 12 and 3 months, respectively, when frozen. The median orexin-A concentration in CSF from narcolepsy type 1 patients was <35 pg/mL (range < 35-131 pg/mL), which was lower than that in CSF from control individuals (98 pg/mL, range < 35-424 pg/mL). Orexin-A concentrations determined using our LC-MS/MS assay were five times lower than those measured with a commercial RIA. Orexin-B concentrations were undetectable.

CONCLUSIONS

Orexin-A concentrations measured by our LC-MS/MS assay were lower in narcolepsy type 1 patients as compared to controls. RIA yielded on average higher concentrations than LC-MS/MS.

Для цитирования: Lindström Mikael, Schinkelshoek Mink, Tienari Pentti J, Kukkonen Jyrki P, Renkonen Risto, Fronczek Rolf, Lammers Gert Jan, Itkonen Outi. Orexin-A measurement in narcolepsy: A stability study and a comparison of LC-MS/MS and immunoassays.. Clinical biochemistry. 2021. DOI: 10.1016/j.clinbiochem.2021.01.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.