MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/tomography8060236

Медицинская библиотека · Tomography (Ann Arbor, Mich.) · 2022

Accuracy of CT-Guided Core-Needle Biopsy in Diagnosis of Thoracic Lesions Suspicious for Primitive Malignancy of the Lung: A Five-Year Retrospective Analysis.

Baratella Elisa, Cernic Stefano, Minelli Pierluca, Furlan Giovanni, Crimì Filippo, Rocco Simone, Ruaro Barbara, Cova Maria Assunta

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Lung cancer represents a heterogeneous group of neoplasms, with the highest frequency and mortality in both sexes combined. In a clinical scenario characterized by the widespread of multidetector-row spiral CT, core-needle biopsy under tomographic guidance is one of the main and safest methods to obtain tissue specimens, even though there are relatively high rates of pneumothorax (0-60% incidence) and pulmonary hemorrhage (4-27% occurrence rates). The aim of this retrospective study is to assess the diagnostic accuracy of CT-guided core-needle biopsy in the diagnosis of primary lung malignancies and to compare our results with evidence from the literature.

MATERIALS AND

METHODS

Our analysis included 350 thoracic biopsies, performed from 2017 to 2022 with a 64-row CT guidance and 16/18 G needles mounted on a biopsy gun. We included in the final cohort all samples with evidence of primary lung malignancies, precursor lesions, and atypia, as well as inconclusive and negative diagnoses.

RESULTS

There was sensitivity of 90.07% (95% CI 86.05-93.25%), accuracy of 98.87% (95% CI 98.12-99.69%), positive predictive value of 100%, and negative value of 98.74% (95% CI 98.23-99.10%). Specificity settled at 100% (93.84-100%). The AUC was 0.952 (95% CI 0.924-0.972). Only three patients experienced major complications after the procedure. Among minor complications, longer distances from the pleura, the presence of emphysema, and the lower dimensions of the lesions were correlated with the development of pneumothorax after the procedure, while longer distances from the pleura and the lower dimensions of the lesions were correlated with intra-alveolar hemorrhage. Immunohistochemistry analysis was performed in 51% of true positive cases, showing TTF-1, CK7, and p40 expression, respectively, in 26%, 24%, and 10% of analyzed samples.

CONCLUSIONS

The CT-guided thoracic core-needle biopsy is an extremely accurate and safe diagnostic procedure for the histological diagnosis of lung cancer, a first-level interventional radiology exam for peripheral and subpleural lesions of the lung, which is also able to provide adequate samples for advanced pathologic assays (e.g., FISH, PCR) to assess molecular activity and genetic sequencing.

Для цитирования: Baratella Elisa, Cernic Stefano, Minelli Pierluca, Furlan Giovanni, Crimì Filippo, Rocco Simone, Ruaro Barbara, Cova Maria Assunta. Accuracy of CT-Guided Core-Needle Biopsy in Diagnosis of Thoracic Lesions Suspicious for Primitive Malignancy of the Lung: A Five-Year Retrospective Analysis.. Tomography (Ann Arbor, Mich.). 2022. DOI: 10.3390/tomography8060236.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.