MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/trstmh/try014

Медицинская библиотека · Transactions of the Royal Society of Tropical Medicine and Hygiene · 2018

Innovative methodology for point-of-care circulating cathodic antigen with rapid urine concentration for use in the field for detecting low Schistosoma mansoni infection and for control of cure with high accuracy.

Grenfell Rafaella F Q, Taboada Diana, Coutinho Lucélia A, Pedrosa Maria Luysa C, Assis Jéssica V, Oliveira Matheus S P, Cruz Renata R, Almeida Aureo, Silva-Moraes Vanessa, Katz Naftale, Coelho Paulo Marcos Z

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Prior to eliminating schistosomiasis, efforts must address accurate and fast individual diagnosis. Diagnosis is still inaccurate by parasitological and point-of-care circulating cathodic antigen (POC-CCA) in areas of low endemicity.

METHODS

Our group has optimized POC-CCA with a 30 min urine concentration step with no need for specialized technicians or equipment and with high accuracy. We evaluated this new method, called POC-CCA filter (FLT), in two Brazilian endemic areas with distinct profiles.

RESULTS

At baseline, POC-CCA had a poor performance with several false results and undefined trace readings, revealing a prevalence rate of 10% against a rate of 23% for POC-CCA FLT, which was similar to the parasitological rates. Accuracy increased from as low as 0.36 to 0.96 after urine concentration in one area. POC-CCA properly diagnosed only half of the cases at three post-treatment time points, while POC-CCA FLT was able to diagnose 96, 83 and 100%, respectively.

CONCLUSIONS

The improvement of conventional POC methodology by a fast and simple urine concentration step provided not only an increase in its accuracy before and after praziquantel treatment, but also preserved its applicability in low-prevalence endemic areas, allowing the definition of trace readings as negative cases.

Для цитирования: Grenfell Rafaella F Q, Taboada Diana, Coutinho Lucélia A, Pedrosa Maria Luysa C, Assis Jéssica V, Oliveira Matheus S P, Cruz Renata R, Almeida Aureo, Silva-Moraes Vanessa, Katz Naftale, Coelho Paulo Marcos Z. Innovative methodology for point-of-care circulating cathodic antigen with rapid urine concentration for use in the field for detecting low Schistosoma mansoni infection and for control of cure with high accuracy.. Transactions of the Royal Society of Tropical Medicine and Hygiene. 2018. DOI: 10.1093/trstmh/try014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.