MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1590/0037-8682-0423-2016

Медицинская библиотека · Revista da Sociedade Brasileira de Medicina Tropical · 2017

Sensitivity and specificity of the circulating cathodic antigen rapid urine test in the diagnosis of Schistosomiasis mansoni infection and evaluation of morbidity in a low- endemic area in Brazil.

Ferreira Fernanda Teixeira, Fidelis Thiago André, Pereira Thiago Almeida, Otoni Alba, Queiroz Leonardo Campos, Amâncio Frederico Figueiredo, Antunes Carlos Maurício, Lambertucci José Roberto

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

: The Kato-Katz technique is the standard diagnostic test for Schistosoma mansoni infection in rural areas. However, the utility of this method is severely limited by the day-to-day variability in host egg excretion in the stool. In high-transmission areas, the point-of-care circulating cathodic antigen (POC-CCA) urine assay has proven to be a reliable test. However, investigations of the reliability of the POC-CCA assay in low-transmission regions are under way. This study aimed to evaluate the sensitivity and specificity of the POC-CCA assay and the morbidity of schistosomiasis in a low-endemic area in Brazil.

METHODS

: Pains City is a low-transmission zone for schistosomiasis. A total of 300 subjects aged 7-76 years were randomly selected for the POC-CCA cassette test. For S. mansoni diagnosis, three stool samples on six slides were compared with one urine sample for each subject. The sensitivity and specificity in the absence of a gold standard were calculated using latent class analysis. Clinical examinations and abdominal ultrasounds were performed in 181 volunteers to evaluate morbidity associated with schistosomiasis.

RESULTS

: The sensitivity and specificity of the Kato-Katz technique were 25.6% and 94.6%, respectively. By contrast, the sensitivity and specificity of the POC-CCA assay were 68.1% and 72.8%, respectively. Hepatosplenic schistosomiasis was diagnosed in two patients (1.1%).

CONCLUSIONS

: Overall, the POC-CCA urine assay proved to be a useful test for diagnosing S. mansoni in a low-endemic area in Brazil. Severe clinical forms of schistosomiasis can be present even in such low-endemic areas.

Для цитирования: Ferreira Fernanda Teixeira, Fidelis Thiago André, Pereira Thiago Almeida, Otoni Alba, Queiroz Leonardo Campos, Amâncio Frederico Figueiredo, Antunes Carlos Maurício, Lambertucci José Roberto. Sensitivity and specificity of the circulating cathodic antigen rapid urine test in the diagnosis of Schistosomiasis mansoni infection and evaluation of morbidity in a low- endemic area in Brazil.. Revista da Sociedade Brasileira de Medicina Tropical. 2017. DOI: 10.1590/0037-8682-0423-2016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.