MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/opx.0b013e318181a92f

Медицинская библиотека · Optometry and vision science : official publication of the American Academy of Optometry · 2008

Subjective and objective variation of the tear film pre- and post-sleep.

Bitton Etty, Keech Adam, Jones Lyndon, Simpson Trefford

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To date, few studies have correlated the overnight effects of the preocular tear film (POTF) with subjective symptoms. This study investigates the POTF volume and stability, bulbar hyperemia (BH), tear ferning (TF) and the participant's subjective symptoms, pre- and post-sleep.

METHODS

Thirty subjects were recruited, consisting of two evenly distributed groups who were symptomatic of dry eye (DE) and those that were asymptomatic dry eye, determined using the McMonnies questionnaire. Subjects were evaluated at 10 p.m. (baseline), on waking at 7 a.m., and then hourly until 10 a.m. At each visit, tear meniscus height (TMH), various subjective factors, BH and POTF stability by non-invasive break-up time (NIBUT) were assessed. Tear collection was performed at 10 p.m, 7 and 10 a.m. for TF analysis.

RESULTS

With the exception of burning, all other symptoms (comfort, dryness, clarity of vision, and grittiness) revealed an overnight change (p < 0.05) within each group, but not between the two groups (p > 0.05). Both the tear meniscus height and BH were elevated upon waking and differed significantly between test times for each group (p < 0.05), but not between groups (p > 0.05). NIBUT was lower for the DE group (p < 0.001). The non-dry eye (NDE) group did not significantly alter over time (p > 0.05), but the DE group did (p = 0.004), with a longer NIBUT in the morning. TF demonstrated a degraded pattern upon waking for both groups (p < 0.05). Most of the changes returned to baseline within an hour after waking.

CONCLUSIONS

The properties of the POTF undergo a change during extended periods of eye closure and the human POTF is different upon waking to that present immediately before sleep. Most of the parameters determined rapidly revert to baseline levels once the POTF is allowed to refresh.

Для цитирования: Bitton Etty, Keech Adam, Jones Lyndon, Simpson Trefford. Subjective and objective variation of the tear film pre- and post-sleep.. Optometry and vision science : official publication of the American Academy of Optometry. 2008. DOI: 10.1097/opx.0b013e318181a92f.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.