MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-025-97336-1

Медицинская библиотека · Scientific reports · 2025

Twelve month refractive and axial length changes in the Israeli refractive error, activity, and devices (iREAD) study.

Shneor Einat, Ostrin Lisa A, Gordon-Shaag Ariela, Levine Jonathan, Sinnott Loraine T, Jones-Jordan Lisa A, Davidson Kevin, Doron Ravid

СтатьяПеревод пока не подготовлен

Аннотация

The Israel Refraction, Environment, and Devices (iREAD) is a longitudinal study assessing myopia risk factors in three groups of boys with distinct lifestyles. Ultra-Orthodox (N = 41), Religious (N = 53), and Secular (N = 41) boys (ages 8.6 ± 1.5 years) had eye exams at baseline and 12 months, including cycloplegic autorefraction and axial length. Ocular history, education, near work, and electronic device use were assessed. Time outdoors and physical activity were measured objectively. At 12 months, myopia prevalence increased from 32 to 40% (P = 0.02), with no group differences (P > 0.05). The Ultra-Orthodox group had a more myopic spherical equivalent refraction (SER) at baseline and 12 months than the Religious and Secular groups and more myopic shift at 12 months (P < 0.05 for all). The Ultra-Orthodox group spent less time using electronic devices, more time in school, read at an earlier age, and had higher parental myopia (P < 0.01 for all). Time outdoors and activity did not differ between groups (P > 0.05 for both). In univariate and multivariate analyses, group and parental myopia were associated with greater myopic shift of SER and axial elongation (P < 0.05). In conclusion, risk factors associated with greater myopia progression included being part of the Ultra-Orthodox educational system and number of myopic parents and not screen use.

Для цитирования: Shneor Einat, Ostrin Lisa A, Gordon-Shaag Ariela, Levine Jonathan, Sinnott Loraine T, Jones-Jordan Lisa A, Davidson Kevin, Doron Ravid. Twelve month refractive and axial length changes in the Israeli refractive error, activity, and devices (iREAD) study.. Scientific reports. 2025. DOI: 10.1038/s41598-025-97336-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.