m+Medelevator.RU
← Поиск публикаций
Artificial intelligence in medicine · 2011

Automatic detection of epileptic seizures on the intra-cranial electroencephalogram of rats using reservoir computing.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Buteneers Pieter, Verstraeten David, van Mierlo Pieter, Wyckhuys Tine, Stroobandt Dirk, Raedt Robrecht, Hallez Hans, Schrauwen Benjamin

Аннотация

INTRODUCTION: In this paper we propose a technique based on reservoir computing (RC) to mark epileptic seizures on the intra-cranial electroencephalogram (EEG) of rats. RC is a recurrent neural networks training technique which has been shown to possess good generalization properties with limited training.

MATERIALS: The system is evaluated on data containing two different seizure types: absence seizures from genetic absence epilepsy rats from Strasbourg (GAERS) and tonic-clonic seizures from kainate-induced temporal-lobe epilepsy rats. The dataset consists of 452hours from 23 GAERS and 982hours from 15 kainate-induced temporal-lobe epilepsy rats.

METHODS: During the preprocessing stage, several features are extracted from the EEG. A feature selection algorithm selects the best features, which are then presented as input to the RC-based classification algorithm. To classify the output of this algorithm a two-threshold technique is used. This technique is compared with other state-of-the-art techniques.

RESULTS: A balanced error rate (BER) of 3.7% and 3.5% was achieved on the data from GAERS and kainate rats, respectively. This resulted in a sensitivity of 96% and 94% and a specificity of 96% and 99% respectively. The state-of-the-art technique for GAERS achieved a BER of 4%, whereas the best technique to detect tonic-clonic seizures achieved a BER of 16%.

CONCLUSION: Our method outperforms up-to-date techniques and only a few parameters need to be optimized on a limited training set. It is therefore suited as an automatic aid for epilepsy researchers and is able to eliminate the tedious manual review and annotation of EEG.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты