PURPOSE: To theoretically and clinically evaluate the impact of axis misalignment of toric intraocular lenses (IOLs) on postoperative refraction.

SETTING

International Vision Correction Research Center, University of Heidelberg, Heidelberg, Germany.

DESIGN

Case series.

METHODS

A method based on mathematical solutions to obliquely crossed spherocylinders was derived according to the pseudophakic refractive properties and used to analyze the impact of toric IOL misalignment on postoperative refraction. The refractive outcomes were theoretically analyzed and actual postoperative outcomes assessed to confirm the theoretically identified impact.

RESULTS

The mean IOL misalignment was 12.5 degrees ± 6.7 (SD). Three main factors had an impact on refractive outcomes: hyperopic change in refractive sphere, reduction in astigmatic correction, and rotation of the astigmatic axis. The mean calculated spherical change was 0.32 ± 0.23 diopters (D) and the actual change, 0.36 ± 0.71 D. The mean calculated reduction in astigmatic correction was 0.65 ± 0.45 D and the actual reduction, 0.95 ± 0.54 D, indicating undercorrection of preexisting astigmatism. The mean calculated absolute astigmatic rotation was 32.7 ± 13.2 degrees (range 8 to 55 degrees) and the actual rotation, 29.1 ± 17.4 degrees. There was a correlation between the calculated and actual reduction (r(2) = 0.51; P = .001) and between the calculated and actual rotation (r(2) = 0.86; P<.001).

CONCLUSION

In addition to a reduction in astigmatic correction, misalignment of toric IOLs induced hyperopic spherical change and astigmatic rotation.

Для цитирования: Jin Haiying, Limberger Il-Joo, Ehmer Angela, Guo Haike, Auffarth Gerd U. Impact of axis misalignment of toric intraocular lenses on refractive outcomes after cataract surgery.. Journal of cataract and refractive surgery. 2010. DOI: 10.1016/j.jcrs.2010.06.066.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.