MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ta.0000000000004079

Медицинская библиотека · The journal of trauma and acute care surgery · 2023

Rapid clearing CT-001 restored hemostasis in mice with coagulopathy induced by activated protein C.

Sim Derek S, Mallari Cornell R, Bauzon Maxine, Hermiston Terry W

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Activated protein C (APC) is one of the mechanisms contributing to coagulopathy, which is associated with high mortality. The counteraction of the APC pathway could help ameliorate bleeding. However, patients also transform frequently from a hemorrhagic state to a prothrombotic state at a later time. Therefore, a prohemostatic therapeutic intervention should take this thrombotic risk into consideration.

OBJECTIVES

CT-001 is a novel factor VIIa (FVIIa) with enhanced activity and desialylated N-glycans for rapid clearance. We assessed CT-001 clearance in multiple species and its ability to reverse APC-mediated coagulopathic blood loss.

METHODS

The N-glycans on CT-001 were characterized by liquid chromatography-mass spectrometry. Three species were used to evaluate the pharmacokinetics of the molecule. The potency and efficacy of CT-001 under APC pathway-induced coagulopathic conditions were assessed by coagulation assays and bleeding models.

RESULTS

The N-glycosylation sites of CT-001 had high occupancy of desialylated N-glycans. CT-001 exhibited 5 to 16 times higher plasma clearance in human tissue factor knockin mice, rats, and cynomolgus monkeys than wildtype FVIIa. CT-001 corrected the activated partial thromboplastin time and thrombin generation of coagulopathic plasma to normal in in vitro studies. In an APC-mediated saphenous vein bleeding model, 3 mg/kg of CT-001 reduced bleeding time in comparison with wildtype FVIIa. The correction of bleeding by CT-001 was also observed in a coagulopathic tail amputation severe hemorrhage mouse model. The efficacy of CT-001 is independent of the presence of tranexamic acid, and the combination of CT-001 and tranexamic acid does not lead to increased thrombogenicity.

CONCLUSION

CT-001 corrected APC pathway-mediated coagulopathic conditions in preclinical studies and could be a potentially safe and effective procoagulant agent for addressing APC-mediated bleeding.

Для цитирования: Sim Derek S, Mallari Cornell R, Bauzon Maxine, Hermiston Terry W. Rapid clearing CT-001 restored hemostasis in mice with coagulopathy induced by activated protein C.. The journal of trauma and acute care surgery. 2023. DOI: 10.1097/ta.0000000000004079.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.