MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s003470100529

Медицинская библиотека · Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft · 2002

[New automated microkeratome for trepanation of lamellar keratoplasty].

Ludwig K, Bechmann M, Welge-Lüssen U, Kenyon K R, Hoops J, Kampik A

Клинический случайАннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND/PURPOSE: Lamellar keratoplasty is an established therapy of corneal pathologies without endothelial involvement and the lack of endothelial rejection is one of the major advantages compared to penetrating keratoplasty. The major disadvantages of manually prepared lamellar corneal grafts are the limited mechanical and optical quality but the automated lamellar therapeutic keratoplasty system ALTK (MORIA) is intended to overcome these disadvantages. The purpose of this preliminary work is to investigate histologically and in clinical cases, if the ALTK system can achieve this aim.

PATIENTS AND

METHODS

Corneas from two human donors were cut with a 300 microns trephine. After fixation, the stromal bed and the excised cup of one specimen were stained with PAS and examined by light microscopy and the other specimen was analyzed by scanning electron microscopy. In addition, follow-up data of two patients who received such a lamellar graft are reported for the first 9 and 7 months postoperation, respectively.

RESULTS

The lamellar cut of homogeneous depth revealed only minor stromal trauma. Both clinical cases demonstrated only minimal interface haze during follow-up. Despite a remarkably clear cornea, visual acuity improved only slowly because the precise lamellar cut tended to partially reproduce any preexisting irregular astigmatism.

CONCLUSIONS

The ALTK system simplifies and standardizes the trephination of lamellar corneal grafts but a longer follow up is necessary with respect to visual development and preservation of a clear graft.

Для цитирования: Ludwig K, Bechmann M, Welge-Lüssen U, Kenyon K R, Hoops J, Kampik A. [New automated microkeratome for trepanation of lamellar keratoplasty].. Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft. 2002. DOI: 10.1007/s003470100529.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.