DOI 10.1097/01.rlu.0000053406.96478.71
Efficiency of gamma probe and dual-phase Tc-99m sestamibi scintigraphy in surgery for patients with primary hyperparathyroidism.
Аннотация
PURPOSE: The purpose of this study was to determine the value of the intraoperative gamma probe and the efficacy of dual-phase Tc-99m sestamibi imaging in patients with primary hyperparathyroidism.
METHODS
Twenty-one patients with primary hyperparathyroidism were examined prospectively. Results of same-day dual-phase Tc-99m sestamibi scintigraphy and intraoperative gamma probe evaluations were compared with the intraoperative findings and histopathologic diagnoses. A 15-mm handheld gamma probe was used to measure gamma activity in the neck and upper mediastinum. Nuclear mapping by gamma probe showed a single quadrant of neck that emitted gamma radiation significantly greater than the other three quadrants, which correlated with the sestamibi scan.
RESULTS
Dual-phase Tc-99m sestamibi scintigraphy determined and localized parathyroid lesions in 20 patients (sensitivity, 94%). Of the 20 parathyroid lesions removed, 15 were located in normal positions, whereas five were explored in ectopic sites (one within the thyroid, one in the anterior mediastinum, one in a retrotracheal position, one in the carotid sheath, and one in the retroesophageal region). Although the index of thyroid nodules varied from 15.8% to 22.9%, the index for parathyroid lesions was 77.3% to 112.8%.
CONCLUSIONS
These results confirm that parathyroid lesions, especially at ectopic sites, can be treated successfully in shorter operative times with minimal complications with the help of the intraoperative gamma probe.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.