DOI 10.1016/j.ajo.2011.06.025

Медицинская библиотека · American journal of ophthalmology · 2011

Corneal hysteresis and Beta-zone parapapillary atrophy.

Hayes Daniel D, Teng Christopher C, de Moraes Carlos Gustavo, Tello Celso, Liebmann Jeffrey M, Ritch Robert

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the relationship between β-zone parapapillary atrophy (βPPA) and corneal hysteresis (CH) in patients with glaucoma.

DESIGN

Prospective, cross-sectional study.

METHODS

Glaucoma patients aged 18 to 90 years with disc photographs within 12 months of the study visit were consecutively enrolled. Exclusion criteria included ocular surgery other than clear corneal phacoemulsification, myopia >6 diopters, contact lens use, and corneal abnormality. CH was measured using the Ocular Response Analyzer (ORA). Disc photographs were evaluated in a masked fashion for βPPA.

RESULTS

We enrolled 99 patients (mean age 67.6 years; 45 men, 54 women). Univariate analysis showed no significant difference in CH between eyes with and without βPPA (8.72 ± 0.23 vs 8.15 ± 0.27 mm Hg, P = .11). There were no differences in corneal resistance factor (CRF) (P = .47), central corneal thickness (CCT) (P = .11), ORA wave score (P = .23), age (P = .23), sex (P = .40), IOP (P = .86), or visual field mean deviation (VFMD) (P = .45). Eyes with βPPA were more myopic (-1.49 ± 0.27 vs -0.22 ± 0.31 diopters, P = .003). Multivariate analysis showed no significant difference in CH between eyes with and without βPPA (P = .38). Eyes with asymmetric βPPA also showed no significant difference in CH (8.97 ± 0.22 vs 9.10 ± 0.22 mm Hg, P = .69).

CONCLUSIONS

We found no significant differences in CH between eyes with and without βPPA or between fellow eyes with asymmetric βPPA.

Для цитирования: Hayes Daniel D, Teng Christopher C, de Moraes Carlos Gustavo, Tello Celso, Liebmann Jeffrey M, Ritch Robert. Corneal hysteresis and Beta-zone parapapillary atrophy.. American journal of ophthalmology. 2011. DOI: 10.1016/j.ajo.2011.06.025.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.