DOI 10.2471/blt.11.088427

Медицинская библиотека · Bulletin of the World Health Organization · 2011

A point-of-care test for measles diagnosis: detection of measles-specific IgM antibodies and viral nucleic acid.

Warrener Lenesha, Slibinskas Rimantas, Chua Kaw Bing, Nigatu Wondatir, Brown Kevin E, Sasnauskas Kestutis, Samuel Dhanraj, Brown David

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the performance of a newly developed point-of-care test (POCT) for the detection of measles-specific IgM antibodies in serum and oral fluid specimens and to assess if measles virus nucleic acid could be recovered from used POCT strips.

METHODS

The POCT was used to test 170 serum specimens collected through measles surveillance or vaccination programmes in Ethiopia, Malaysia and the Russian Federation: 69 were positive for measles immunoglobulin M (IgM) antibodies, 74 were positive for rubella IgM antibodies and 7 were positive for both. Also tested were 282 oral fluid specimens from the measles, mumps and rubella (MMR) surveillance programme of the United Kingdom of Great Britain and Northern Ireland. The Microimmune measles IgM capture enzyme immunoassay was the gold standard for comparison. A panel of 24 oral fluids was used to investigate if measles virus haemagglutinin (H) and nucleocapsid (N) genes could be amplified by polymerase chain reaction directly from used POCT strips.

FINDINGS: With serum POCT showed a sensitivity and specificity of 90.8% (69/76) and 93.6% (88/94), respectively; with oral fluids, sensitivity and specificity were 90.0% (63/70) and 96.2% (200/208), respectively. Both H and N genes were reliably detected in POCT strips and the N genes could be sequenced for genotyping. Measles virus genes could be recovered from POCT strips after storage for 5 weeks at 20-25 °C.

CONCLUSION

The POCT has the sensitivity and specificity required of a field-based test for measles diagnosis. However, its role in global measles control programmes requires further evaluation.

Для цитирования: Warrener Lenesha, Slibinskas Rimantas, Chua Kaw Bing, Nigatu Wondatir, Brown Kevin E, Sasnauskas Kestutis, Samuel Dhanraj, Brown David. A point-of-care test for measles diagnosis: detection of measles-specific IgM antibodies and viral nucleic acid.. Bulletin of the World Health Organization. 2011. DOI: 10.2471/blt.11.088427.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.