m+Medelevator.RU
← Поиск публикаций
Emergency radiology · 2025

Can contrast-enhanced CT assist in the early assessment of biliary obstruction? A quantitative attenuation-based study.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Emir Sevde Nur, Karamustafao Görkem, Aykut Hüseyin, Emir Servet, Kulalı Fatma

Аннотация

PURPOSE: To evaluate the diagnostic utility of bile duct attenuation measured on contrast-enhanced computed tomography (CT) in differentiating choledocholithiasis, malignant biliary obstruction, benign biliary obstruction, and cholangitis.

METHODS: This retrospective study included 208 patients who underwent contrast-enhanced abdominal CT followed by endoscopic retrograde cholangiopancreatography (ERCP) within three days. Intraductal bile attenuation was measured using two region of interest (ROI) techniques (elliptical and 4-point), with all measurements obtained strictly from bile-filled ductal segments. Secondary morphologic features were also assessed. Diagnostic performance was evaluated using receiver operating characteristic (ROC) analysis, and multivariate logistic regression identified independent predictors of malignancy.

RESULTS: Mean attenuation values were significantly higher in malignant obstruction and choledocholithiasis than in benign biliary obstruction and cholangitis (p < 0.001). For malignant obstruction, the 4-point method yielded 96% sensitivity and 81% specificity at a cut-off of ≥ 29 HU (AUC: 0.97), while the elliptical method yielded 100% sensitivity and 80% specificity at ≥ 60 HU (AUC: 0.95). Elliptical ROI attenuation and bile duct wall thickness were independent predictors of malignancy (p = 0.010 and p < 0.001, respectively). Interobserver agreement was excellent for both techniques (ICC > 0.89).

CONCLUSION: When measured strictly within bile-filled ductal segments, CT-based attenuation provides useful quantitative information for differentiating common causes of biliary obstruction. Combined with ductal wall thickness and secondary morphologic features, attenuation analysis may enhance the diagnostic value of routine contrast-enhanced CT, particularly in settings where advanced imaging modalities are limited or delayed.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты