MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2471/blt.11.087627

Медицинская библиотека · Bulletin of the World Health Organization · 2011

Sensitivity and specificity of typhoid fever rapid antibody tests for laboratory diagnosis at two sub-Saharan African sites.

Keddy Karen H, Sooka Arvinda, Letsoalo Maupi E, Hoyland Greta, Chaignat Claire Lise, Morrissey Anne B, Crump John A

Оценочное исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate three commercial typhoid rapid antibody tests for Salmonella Typhi antibodies in patients suspected of having typhoid fever in Mpumalanga, South Africa, and Moshi, United Republic of Tanzania.

METHODS

The diagnostic accuracy of Cromotest(®) (semiquantitative slide agglutination and single tube Widal test), TUBEX(®) and Typhidot(®) was assessed against that of blood culture. Performance was modelled for scenarios with pretest probabilities of 5% and 50%.

FINDINGS: In total 92 patients enrolled: 53 (57.6%) from South Africa and 39 (42.4%) from the United Republic of Tanzania. Salmonella Typhi was isolated from the blood of 28 (30.4%) patients. The semiquantitative slide agglutination and single-tube Widal tests had positive predictive values (PPVs) of 25.0% (95% confidence interval, CI: 0.6-80.6) and 20.0% (95% CI: 2.5-55.6), respectively. The newer typhoid rapid antibody tests had comparable PPVs: TUBEX(®), 54.1% (95% CI: 36.9-70.5); Typhidot(®) IgM, 56.7% (95% CI: 37.4-74.5); and Typhidot(®) IgG, 54.3% (95% CI: 36.6-71.2). For a pretest probability of 5%, PPVs were: TUBEX(®), 11.0% (95% CI: 6.6-17.9); Typhidot(®) IgM, 9.1% (95% CI: 5.8-14.0); and Typhidot(®) IgG, 11.0% (6.3-18.4). For a pretest probability of 50%, PPVs were: TUBEX(®), 70.2% (95% CI: 57.3-80.5); Typhidot(®) IgM, 65.6% (95% CI: 54.0-75.6); and Typhidot(®) IgG, 70.0% (95% CI: 56.0-81.1).

CONCLUSION

Semiquantitative slide agglutination and single-tube Widal tests performed poorly. TUBEX(®) and Typhidot(®) may be suitable when pretest probability is high and blood cultures are unavailable, but their performance does not justify deployment in routine care settings in sub-Saharan Africa.

Для цитирования: Keddy Karen H, Sooka Arvinda, Letsoalo Maupi E, Hoyland Greta, Chaignat Claire Lise, Morrissey Anne B, Crump John A. Sensitivity and specificity of typhoid fever rapid antibody tests for laboratory diagnosis at two sub-Saharan African sites.. Bulletin of the World Health Organization. 2011. DOI: 10.2471/blt.11.087627.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.