MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1540-8159.2010.02970.x

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2010

Noncavotricuspid isthmus-dependent right atrial tachycardia after paroxysmal atrial fibrillation ablation.

Ju Weizhu, Yang Bing, Chen Hongwu, Zhang Fengxiang, Zhai Lishang, Cao Kejiang, Chen Minglong

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Atrial tachycardia (AT) is commonly encountered after atrial fibrillation (AF) ablation. But no study exclusively on noncavotricuspid isthmus-dependent right AT (NCTI-RAT) post-AF ablation has been reported. The present study aims to describe its prevalence, electrophysiological mechanisms, and ablation strategy and to further discuss its relationship with AF.

METHODS

From July 2006 to November 2009, 350 consecutive patients underwent catheter ablation for paroxysmal AF. A total of seven patients (2.0%) developed NCTI-RAT after left atrium ablation for AF. In these highly selected patients (two male, mean age 54 ± 11 years, mean left atrium diameter of 34 ± 7 cm), all had circumferential pulmonary vein isolation in their initial procedures and three of them had additional complex fractionated electrograms ablation in the left atrium and the coronary sinus.

RESULTS

Totally, nine NCTI-RATs were mapped and successfully ablated in the right atrium with a mean cycle length of 273 ± 64 ms in seven patients. Five ATs in three patients were electrophysiologically proved to be macroreentry and the remaining four were focal activation. All the ATs were successfully abolished by catheter ablation. After a mean follow-up of 29 ± 15 months post-AT ablation, all patients were free of AT and AF off antiarrhythmic drugs.

CONCLUSIONS

NCTI-RAT is relatively less common post-AF ablation. Totally, 2.0% of paroxysmal AF patients were revealed to have NCTI-RAT.

Для цитирования: Ju Weizhu, Yang Bing, Chen Hongwu, Zhang Fengxiang, Zhai Lishang, Cao Kejiang, Chen Minglong. Noncavotricuspid isthmus-dependent right atrial tachycardia after paroxysmal atrial fibrillation ablation.. Pacing and clinical electrophysiology : PACE. 2010. DOI: 10.1111/j.1540-8159.2010.02970.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.