Inter-operator variation in ELISPOT analysis of measles virus-specific IFN-gamma-secreting T cells.

Ryan J E, Ovsyannikova I G, Dhiman N, Pinsky N A, Vierkant R A, Jacobson R M, Poland G A

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

The ELISPOT assay is a highly sensitive technique used for the detection of individual cytokine releasing cells. We have developed an IFN-gamma ELISPOT assay utilizing unfractionated frozen peripheral blood mononuclear cells (PBMC) to quantify the frequency of measles virus (MV)-specific IFN-gamma-secreting T cells in 117 healthy children who had been previously immunized with two doses of the measles-mumps-rubella vaccine. We have also estimated the variability associated with the quantification of ELISPOT plates and compared the number of MV-specific IFN-gamma-secreting T cells for each subject as determined by two different operators of an ELISPOT reader. The median frequency of MV-specific IFN-gamma-producing memory T cells detected by this assay was 0.005 % and 0.01 % as determined by an in-house and commercial operator, respectively. Although we found a significant correlation (r = 0.83, p<0.0001) between the number of spots counted by the commercial and in-house operators of an ELISPOT reader, the median number of spots counted by the commercial operator was twice the number of spots counted by an in-house operator (p<0.001). This demonstrates the importance of using a common ELISPOT reader and operator, among other parameters, to quantify the number of spots when a large volume of plates are being scanned and analyzed.

Для цитирования: Ryan J E, Ovsyannikova I G, Dhiman N, Pinsky N A, Vierkant R A, Jacobson R M, Poland G A. Inter-operator variation in ELISPOT analysis of measles virus-specific IFN-gamma-secreting T cells.. Scandinavian journal of clinical and laboratory investigation. 2005. DOI: 10.1080/00365510500348252.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.