MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0002-8703(03)00429-0

Медицинская библиотека · American heart journal · 2003

Death in patients with permanent pacemakers for sick sinus syndrome.

Flaker Greg, Greenspon Arnold, Tardiff Barbara, Schron Eleanor, Goldman Lee, Hellkamp Anne, Lee Kerry, Lamas Gervasio, Mode Selection Trial (MOST) Investigators

Клиническое исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Although more than one million patients in the United States have permanent pacemakers, little is known about their cause of death. We evaluated the cause of death in 404 patients who died in the Mode Selection Trial (MOST).

METHODS

In MOST, patients received a dual-chamber pacemaker randomly programmed to either dual-chamber or ventricular pacing. The circumstances surrounding each death were reviewed by a clinical events committee, which used prospectively defined criteria to adjudicate the cause of death.

RESULTS

A total of 2010 patients with a median age of 74 years were included. After a median follow-up of 33 months, 404 (20%) patients died, including 198 (49%) of noncardiac causes and 143 (35.4%) of cardiac causes. In 63 patients, the cause of death was unknown. Independent predictors of death through the use of a multivariable analysis were (1) demographic factors including age, male sex, and weight; (2) clinical factors including prior myocardial infarction, cardiomyopathy, New York Heart Association class III/IV, and the Charlson Comorbidity Index; and (3) scores from two measures of functional status, the Karnofsky Score and the Mini-Mental State Examination. Independent predictors of cardiovascular death were similar.

CONCLUSIONS

Patients treated with permanent pacemakers for sinus node dysfunction are elderly and have a substantial mortality rate, with more than half the classifiable deaths being noncardiac. Baseline demographic variables and scores from quality-of-life measures can identify patients with the highest risk of death.

Для цитирования: Flaker Greg, Greenspon Arnold, Tardiff Barbara, Schron Eleanor, Goldman Lee, Hellkamp Anne, Lee Kerry, Lamas Gervasio, Mode Selection Trial (MOST) Investigators. Death in patients with permanent pacemakers for sick sinus syndrome.. American heart journal. 2003. DOI: 10.1016/s0002-8703(03)00429-0.