MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00134-015-3998-4

Медицинская библиотека · Intensive care medicine · 2015

Hemodynamic assessment of ventilated ICU patients with cardiorespiratory failure using a miniaturized multiplane transesophageal echocardiography probe.

Begot Emmanuelle, Dalmay François, Etchecopar Caroline, Clavel Marc, Pichon Nicolas, Francois Bruno, Lang Roberto, Vignon Philippe

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the feasibility, image quality, diagnostic accuracy, therapeutic impact and tolerance of diagnostic and hemodynamic assessment using a novel miniaturized multiplane transesophageal echocardiography (TEE) probe in ventilated ICU patients with cardiopulmonary compromise.

STUDY

DESIGN

Prospective, descriptive, single-center study.

METHODS

Fifty-seven ventilated patients with acute circulatory or respiratory failure were assessed, using a miniaturized multiplane TEE probe and a standard TEE probe used as reference, randomly by two independent experienced operators. Measurements of hemodynamic parameters were independently performed off-line by a third expert. Diagnostic groups of acute circulatory failure (n = 5) and of acute respiratory failure (n = 3) were distinguished. Hemodynamic monitoring was performed in 9 patients using the miniaturized TEE probe. TEE tolerance and therapeutic impact were reported.

RESULTS

The miniaturized TEE probe was easier to insert than the standard TEE probe. Despite lower imaging quality of the miniaturized TEE probe, the two probes had excellent diagnostic agreement in patients with acute circulatory failure (Kappa: 0.95; 95% CI: 0.85-1) and with acute respiratory failure (Kappa: 1; 95% CI: 1.0-1.0). Accordingly, therapeutic strategies derived from both TEE examinations were concordant (Kappa: 0.82; 95% CI: 0.66-0.97). The concordance between quantitative hemodynamic parameters obtained with both TEE probes was also excellent. No relevant complication secondary to TEE probes insertion occurred.

CONCLUSIONS

Hemodynamic assessment of ventilated ICU patients with cardiopulmonary compromise using a miniaturized multiplane TEE probe appears feasible, well-tolerated, and relevant in terms of diagnostic information and potential therapeutic impact. Further larger-scale studies are needed to confirm these preliminary results.

Для цитирования: Begot Emmanuelle, Dalmay François, Etchecopar Caroline, Clavel Marc, Pichon Nicolas, Francois Bruno, Lang Roberto, Vignon Philippe. Hemodynamic assessment of ventilated ICU patients with cardiorespiratory failure using a miniaturized multiplane transesophageal echocardiography probe.. Intensive care medicine. 2015. DOI: 10.1007/s00134-015-3998-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.